INSTALLATION AND START-UP MANUALFOR KOMPACT AML DOSING
Packing contents:
A. Opaque hose for connecting the pump's outlet to the
injection point
B. Transparent hose for suction and for connecting the
bleeding valve up for manual priming
C. Injection fitting
D. Hose connection kit
E. Bottom filter
F. Wall mounting bracket
G. Anchors for securing the pump to the wall
H. Screw protection caps
I.
Instructions Manual
FOR SPECIFIC HYDRAULIC FEATURES SEE THE LABEL ON THE PUMP
INTRODUCTION
The pump is composed of a part that houses the control electronics and the magnet and a hydraulic side always in contact with
the liquid to be dosed.
Check the rating plate of the main features of your pump
We recommend checking the chemical compatibility between the product and the materials in contact.
PUMP HEAD MATERIALS
•
Pump body:
•
Valves:
•
Balls:
•
Diaphragm:
SPECIFICATIONS
•
Weight:
•
Power Supply:
•
Consumption:
•
Fuse:
•
Protection rating:
•
Level control input:
EM00136454
PUMP
PVDF-T
PVDF-T
Ceramic
PTFE
1.5 Kg
100 - 240 Vac (50-60 Hz) - 24Vac/dc
13W @ 100 Vac – 19W @ 240 Vac – 25W @ 24 Vac/dc
2A (100 ÷ 240 Vac) / 3,15 (24V); 250V; T 5x20
IP65
Dry contact (on-off)
rev.1.0
A
E
1. Adjustments area
2. Dosing head
3. Priming valve
4. Delivery connector
5. Suction connector
6. Base fixing bracket (optional)
EN
C
B
D
F
G
H
I
1