4. CONTROLS
A
Button Function
PANEL CLOSED
Brief Pressure: Activates the keyboard functions.
The panel opens after 1 second and the motor starts
at speed one (B).
PANEL OPEN
A
Brief pressure: Deactivates the keyboard
functions.
- When pressed for 3 sec., the panel closes
with keyboard active.
MOTOR ON
Brief pressure: Motor off.
B
Activates speed one.
C
Activates speed two.
D
Activates speed three.
Activates INTENSIVE 1 speed for 10 minutes. At
the end of this time the system will automatically
return to the speed set before. It is disabled by
changing speed or pressing button A.
E
Press and hold the button for approximately 3 sec-
onds, with all the loads turned off (Motor), to turn the
Activated Charcoal Filter alarm on/off.
Activates BREEZE speed for 60 minutes. At
F
the end of this time the motor switches off. It is
disabled by changing speed or pressing button A.
Filter alarm button.
This button is normal off. It is only displayed with the
filter alarm is triggered. The alarm can be reset by
pressing and holding this button for approximately
G
3 seconds.
WARNING! Comands are only given when the keyboard is active. If the keyboard is off,
press button "A" briefly.
B
C
D
E
F
Led
The buttons turn white.
If the motor does not start the buttons switch
off after 1 minute.
All the buttons are on.
The button turns from white to red.
The button turns from white to red.
The button turns from white to red.
The button turns from white to red.
H flashes 5 times.
The button turns from white to red.
Button H is on fixed (30 seconds): indicates
the need to wash the metal grease filters. The
alarm is triggered after the Hood has been in
operation for 40 working hours.
Button H flashing (30 seconds): indicates the
need to change the activated charcoal filters,
and also to wash the metal grease filters. The
alarm is triggered after the Hood has been in
operation for 160 working hours.
ENGLISH
7
G