FALMEC Lumina Manual De Instrucciones página 15

Ocultar thumbs Ver también para Lumina:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

FUMES DISCHARGE
EXTERNAL EXHAUST HOOD (SUCTION)
In this version the fumes and vapours are discharged
outside through the exhaust pipe.
To this end, the hood outlet fitting must be connected
via a pipe, to an external output.
The outlet pipe must have:
• a diameter not less than that of the hood fitting.
• a slight slope downwards (drop) in the horizontal sections to prevent
condensation from flowing back into the motor.
• the minimum required number of bends.
• the minimum required length to avoid vibrations and reduce the
suction performance of the hood.
You are required to insulate the pipes if it passes through cold envi-
ronments.
In the presence of motors with 500 CFM or higher, a check valve is
present to prevent external air flowing back.
HOOD WITH INTERNAL RECIRCULATION (FILTERING)
In this model, air passes through the active carbon fil-
ters HP (optional) to be purified and is then recycled
into the environment. Ensure that the active carbon fil-
ters HP are assembled into the hood, if not, install them
as indicated in the assembly instructions.
In this version the check valve must not be assembled: re-
move it if it is on the air outlet fitting of the motor.
ASSEMBLY INSTRUCTIONS
only intended for personnel qualified
The hood can be installed in various configurations.
The generic assembly steps apply to all installations;
for each case, follow the specific steps provided for the
required installation.
OPERATION
WHEN TO TURN ON THE HOOD?
Switch on the hood at least one minute before starting to cook to direct
fumes and vapours towards the suction surface.
After cooking, leave the hood operating until complete extraction of all
vapours and odours. By means of the Timer function, it is possible to set
auto switch-off function which will allow the hood to turn off automat-
ically after 15 minutes of operation.
WHICH SPEED IS TO BE SELECTED?
1st speed: maintains the circulation of clean air with low electricity
consumption.
2nd speed: normal conditions of use.
3rd speed: presence of strong odours and vapours.
4th speed: rapid disposal of odours and vapours.
WHEN SHOULD THE FILTERS BE WASHED OR REPLACED?
The metal filters must be cleaned every 30 hours of operation.
The active carbon filters must be replaced every 3-4 months, depend-
ing on the use of the hood.
For further details see the "MAINTENANCE" chap.
ELECTRONIC PUSHBUTTON PANEL (PLANE NRS)
Motor ON/OFF
Upon start-up, the speed is that stored at the previous op-
eration.
Increase speed from 1 to 4
Speed 4 is only active for a
few minutes, then speed 3
activates.
Reduce speed from 4 to 1
Light on/off
TIMER (red LED flashing)
Auto switch-off after 15 min.
The function deactivates (red LED off ) if:
- The TIMER key ( ) is pressed again.
- The ON/OFF key ( ) is pressed.
FILTER ALARM (red LED steady on with ( ) off)
Anti-grease filter maintenance after approximately 30 hours
of operation.
Press ( ) the meter for 3 seconds to reset.
TOUCH PUSHBUTTON PANEL (LUMINA NRS)
ON/OFF (Blue led steady on)
Motor on/off and Speed 1
ON/OFF (blue led flashing)
If pressed for more than 3 seconds, it activates the 24h cycle
(1h ON -> 3h OFF -> 1h ON)
the function deactivates if:
- The motor turns off (key
- After 24h
Speed 2 activation
Speed 3 activation
Speed 4 activation for a few minutes only
Light on/off
TIMER (Red LED flashing)
Auto switch-off after 15 min.
The function deactivates (red LED off ) if:
- The motor turns off (key
- The speed is changed.
FILTER ALARM (red LED steady on)
Anti-grease filter maintenance after approximately 30 hours
of operation.
Press the meter for 3 seconds to reset.
15
The speeds are indicated by
the LEDs on the keys:
Speed 1
Speed 2
Speed 3
Speed 4
("+" LED flashing)
)
).
Tabla de contenido
loading

Este manual también es adecuado para:

PlaneFnlum36w5ssFnpls30w5ssFnpls36w5ss

Tabla de contenido