Failure
The unit does not start
The Unit does not suck in
any product
The unit sucks in but does
not reach the necessary
pressure (it does not stop
when the gun is closed)
The product hose vibrates
abnormally
The unit sucks in and builds
up pressure when the valve
is closed, but it decreases
too much when the trigger is
pulled
Abnormal spray pattern
("Horns" and streaks)

19. TROUBLESHOOTING

Cause of the failure
Compressed air supply malfunctioning
Malfunction in the pneumatic System
Pressurised Unit
The product container is empty
The suction Filter is obstructed
The suction Probe is loose, blocked or damaged
The pressure Regulator is set at minimum
The purge Valve is closed
The suction Probe is stuck, dirty or damaged
The outlet valve is stuck, dirty or damaged
Seal in poor condition
The purge valve is open or faulty
The outlet valve is dirty or damaged (It does not
stop when travelling up nor when travelling down)
The Filter is dirty or the suction probe is damaged
There are pockets of air in the Piston
The outlet valve is dirty or faulty
The bottom Gasket of the Piston valve is faulty
The suction Probe and/or the suction Probe are
loose, dirty or damaged
The suction Probe is damaged
The Gun has no Aircap
The anti-pulsation Filter is blocked
The aircap is worn
The product is too thick
The pump Pressure is low
The product Filter is blocked
The Aircap is damaged
The anti-pulsation Filter is blocked
The suction Probe and/or the suction Probe are
loose, dirty or damaged
- 22 -
Repair
Make sure the supply hose is not obstructed
Make sure the unit is properly connected to
the mains supply
Make sure the compressed air valve is
open
Consult SAT SAGOLA
Depressurise the unit (See Depressurisation
Procedure described in the Manual)
Refill it
Clean it or replace it
Check the connection of the probe to the
unit or replace it
Increase the pressure by adjusting the
regulator
Open it
Remove it and clean or replace it
Remove it and clean or replace it
Replace it
Close it or replace it
Clean it or replace it
Clean it or replace it
Adjust the pressure Regulator (Maximum-
Minimum) to eliminate the pockets of air
Clean it or replace it
Replace it
Tighten and/or clean the Probe and Filter, or
replace elements
Replace it
Assemble the cap
Clean it or Replace it
Replace it
Reduce its thickness
Increase the pressure by adjusting the
pressure Regulator
Clean it or Replace it
Replace it
Clean it or Replace it
Tighten and/or clean the Probe and Filter, or
replace elements