TECHNICAL DATA
MODEL
TYPE
OUTPUT
(1)
FUEL
- net calorific value
- absolute density
- max delivery
- pressure at max. delivery (2)
OPERATION
STANDARD APPLICATION
AMBIENT TEMPERATURE
COMBUSTIVE AIR TEMPERATURE
ELECTRICAL SUPPLY
ELECTRICAL MOTOR
ACCELERATION CURRENT
OPERATION CURRENT
MOTOR CAPACITOR
IGNITION TRASFORMER
ELECTRICAL POWER CONSUMPTION
ELECTRICAL PROTECTION
IN CONFORMITY WITH EEC DIRECTIVES
NOISE
(3)
APPROVAL
(1) Reference conditions: Room temperature 20°C - Gas temperature 15°C - Barometric pressure 1013 mbar - Altitude 0m above sea level.
(2) Socket pressure 7)(A)p.3 with zero pressure in the combustion chamber.
(3) Sound pressure measured in the manufacturer's combustion laboratory, with burner operating on the test boiler at maximum output and
measured from one metre away at the frequency of 50Hz.
VARIANTS
POWER
MODEL
SUPPLY
single-phase
RS 34 MZ
single-phase
single-phase
single-phase
RS 44 MZ
three-phase
three-phase
ACCESSORIES (optional):
• KIT LONG HEAD
BURNER
Code
• KIT FOR LPG OPERATION: the kit allows the RS 34-44MZ burners to operate on LPG.
BURNER
Output kW
Blast tube length mm
Code
• GAS TRAINS TO COUPLE WITH THE BURNER, ACCORDING TO REGULATION EN 676 (complete with valves, pressure adjuster andfilter): see page 8.
• MAXIMUM GAS PRESSURE SWITCH cod. 3010418
• CLEAN CONTACTS KIT cod. 3010419
NOTE: The installer is responsible for the addition of any safety device not foreseen in this manual.
All manuals and user guides at all-guides.com
2nd stage
kW
Mcal/h
min. 1st
kW
stage
Mcal/h
NATURAL GAS: G20 - G21 - G22 - G23 - G25
G20
3
kWh/Sm
9.45
3
8.2
Mcal/Sm
3
0.71
kg/Sm
3
41
Sm
/h
mbar
7.1
• Intermittent (min. 1 stop in 24 hours)
• Two-stage (high and low flame) and one-stage (all - nothing)
Boilers: water, steam, diethermic oil
°C
0 - 40
°C max
60
V
230 ~ +/-10%
Hz
50/60 - single-phase
rpm
W
V
A
A
mF/V
V1 - V2
230 V - 1 x 15kV
I1 - I2
1 A - 25mA
W max
IP40
90/396 - 89/336 - 73/23 - 92/42
dBA
CE
LENGTH
BLAST TUBE mm
216
351
216
351
216
351
RS 34 MZ
3010428
RS 34 MZ
in progress
216 - 351
3010423
RS 34 MZ
RS 44 MZ
883 T
884 T
125 - 390
200 - 550
108 - 336
172 - 473
70
100
60
86
G25
G20
8.13
9.45
7.0
8.2
0.78
0.71
48
58
10.7
9
2800/3400
2820/3400
300
420
220 - 240
220 - 240
15
17
3.2
3.5
12.5/400
12.5/425
600
700
70
72
0085BR0381
GAS CATEGORY
COUNTRY
IT - AT - GR - DK - FI - SE
ES - GB - IE - PT
NL
FR
DE
BE
LU
RS 44 MZ
3010429
RS 44 MZ
100/200 - 530kW
216 - 351
3010424
2
GB
RS 44 MZ
884 T
200 - 550
172 - 473
100
86
G25
G20
G25
8.13
8.13
9.45
7.0
7.0
8.2
0.78
0.78
0.71
67.6
67.6
58
13.5
9
13.5
230 - 400 with neutral ~ +/-10%
50/60 - three-phase
2820/3400
450
220/240-380/415
14 - 10
2 - 1.4
-
800
72
CATEGORY
II
2H3B / P
II
2H3P
II
2L3B / P
II
2Er3P
II
2ELL3B /P
I
I
2E(R)B,
3P
II
2E 3B/P