Optional Lphw - Calorex DH66 Manual Del Usuario

Ocultar thumbs Ver también para DH66:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

4.2 OPTIONAL LPHW

Connect the flow and return water circuit pipe work by means of the 15mm stubs which are
provided on the side of the machine. The connections project 40mm out from the left hand side
of the DH44 and the right hand side of th DH66.
Attention! Flow - bottom connection
Return - top connection
The 3 way, motorised, diverting valve fitted to machines with the LPHW option is operated by a
remote 12V AC air temperature thermostat (available from Calorex).
When the valve is energised the flow is through the LPHW coil.
When the valve is unenergised the flow is diverted.
NOTE :- When the fan switch is set to cycle and the fan is not running, a demand on the LPHW
valve will cause the fan to automatically start.
LPHW PLUMBING SCHEMATIC
All manuals and user guides at all-guides.com
BOILER
PUMP
RADIATORS IF FITTED
COOL
WATER OUT
HOT
WATER IN
22.00
DH44
LPHW INLET AND OUTLET POSITIONS
Page 10
3 WAY MOTORISED VALVE
CONTROLLED BY CUSTOMERS
THERMOSTAT
LPHW
CONNECTIONS
LOCATED ON
DEHUM CABINET
COOL
WATER OUT
HOT
WATER IN
22.00
DH66
Tabla de contenido
loading

Este manual también es adecuado para:

Dh44

Tabla de contenido