15. When the restoration is properly seated, remove excess
cement. Excess cement is best removed in its gel state with a
scaler or explorer. Gel state can be achieved by tack-curing
excess with a light for approximately 2-3 seconds, or by
allowing the cement to self-cure until it feels rubbery.
16. Finish the restoration and check occlusion when material has
completely set. Material should completely set within 4'30"
after placement in the mouth.
17. Remove the used mixing tip and replace it with the sealing
cap.
18. Do not leave the used mixing tip on the syringe for a long
period of time.
19. When only a small amount of paste remains in the syringe, the
paste may not be dispensed from the mixing tip.
Note: Material minimum working time is 1'30" at ambient
temperature; Set time is less than 4'30" at oral
temperature. These times may vary based on storage
conditions, temperature, humidity, and age of product.
STORAGE: Store between 4°C (39°F) and 25°C (77°F). This product
is designed to be used at room temperature. If stored in a cooler,
allow the product to reach room temperature prior to use. Ambient
temperatures greater than 25°C (77°F) may affect shelf life or
product performance. See outer package for expiration date.
Keep product in foil package until initial use. Once the foil pouch is
opened, use the product within 4 months and prior to expiration
date printed on syringe label.
Do not allow the pastes to dry out. Store with cap securely
attached to the syringe. Leaving a used mixing tip on the syringe
as a cap until the next application may result in evaporation and
drying of the paste (not recommended).
Note: Mixing tips, intra-oral tips and root canal tips are for single
patient use only to prevent cross-contamination between patients.
4