2VV FINESSE SUPERIOR control Instalación E Instrucciones De Uso página 5

Tabla de contenido
1. INSTALACIÓN
SUPERIOR MASTER
Módulo de regulación Slave SUPERIOR
VCS-R4-SU-*-
INPUT
Entrée
0-10
0-10
24VAC
24VAC
24VAC
VDC
GND
VDC
GND
1
2
1
1
2
24V
24V
GND
GND
24V
23 24
23 24
23 24
25 26
25 26
1
1
2
1
24VAC
2
24VAC
24VAC
0-10V
24VAC
24VAC
0-10V
24VAC
MIX. POINT / OUTDOOR
POWER SUPPLY
POWER SUPPLY
MIX. POINT / OUTDOOR
POWER SUPPLY
Vanne/ Groupe Exterieur DX
Alimentation
Alimentation
Vanne/ Groupe Exterieur DX
Alimentation
UNIT DX
MIX POINT
MIX POINT
UNIT DX
MIX POINT
vanne
vanne
vanne
alimentation générale
HEATER/
VENT-EXT
VENT-INT
HEATER/
VENT-EXT
VENT-EXT
24VAC
PREHEATER
24VAC
24VAC
PREHEATER
24VAC
REC/BYP
REC/BYP
RPM
RPM
GND GND
RPM
RPM
1
COOL/PUMP
COOL/PUMP
1
GND
GND
PWM
PWM
GND
GND
1
GND
PWM
GND
GND
1
PWM
GND
~
~
~
~
2
~
~
~
~
2
0-10V
(TC)
2
0-10V GND
0-10V GND
(TC)
2
0-10V
(TC)
GND
0-10V
0-10V
GND
13 14
15
25 26 27 28 29
16 17 18 19 20 21 22 23 24
25 26 27 28 29
30
31
30
31
12
11
10
9
8
FUSE
FUSE
7
(VENT-EXT)
(VENT-INT)
6
5
4
FUSE
FUSE
(PCB)
(PERIPHERY)
3
2
83
82
81 80 79 78 77 76 75 74 73
72 71
68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51
72 71
70 69
70 69
68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51
1
L
L
LO
LO
N
N
N
L
LO
L
LO
L
LO
N
ALARM
ALARM
RUN
RUN
COOL/HEAT
COOL/HEAT
ALARM
ERROR
N
ERROR
230VAC
230VAC
230VAC
230VAC
230VAC
230VAC
HEATER
HEATER
OUTPUT
OUTPUT
HEAT PUMP
HEAT PUMP
HEATER
HEAT PUMP
HEAT PUMP
W. PUMP
PIR
FLAP-INT
FLAP-EXT
W. PUMP
W. PUMP
230VAC
230VAC
230VAC
WATER
WATER
WATER
POMPE
POMPE
POMPE
PUMP CONTROL
DE CIRCULATION
OUTPUT
OUTPUT
72 71
77 78
76 75
76 75
72 71
76 75
6
6
6
DX = ON/OFF
DX = ON/OFF
DX = ON/OFF
DX = ON/OFF
7
DX = ON/OFF
7
5
OUTLET
(Sortie pour unité
(Sortie pour unité
(Output for outdoor unit)
(Sortie pour unité
(Output for outdoor unit)
(Output for outdoor unit)
Registre
exterieure)
exterieure)
Air Rejeté
68 67
70 69
70 69
68 67
70 69
!
!
DX GENERAL ERROR
DX GENERAL ERROR
DX DEFROST
8
8
9
8
9
(settable)
(settable)
PRESENCE
CAPTEUR
PRESENCE
CAPTEUR
E
VCS-R4-SU-*-
1
2
3
0-10
VDC
GND
2
GND
24
23
22
20
25 26
49 50
49 50
EXT. SENSOR
EXT. SENSOR
3
2
3
Capteur Externe.
Capteur Externe.
0-10V
MIX. POINT / OUTDOOR
(two-wire shielded cable)
(two-wire shielded cable)
Câble deux fils blindé
Vanne/ Groupe Exterieur DX
Câble deux fils blindé
UNIT DX
HEATER/
24VAC
PREHEATER
24VAC
POSTHEATER
POSTHEATER
REC/BYP
POSTHEATER
T-EXT-1 T-EXT-2 T-EXT-3 T-INT-1 T-INT-2
T-EXT-1 T-EXT-2 T-EXT-3 T-INT-1 T-INT-2
1
COOL/PUMP
T-EXT-1 T-EXT-2 T-EXT-3 T-INT-1 T-INT-2
1
+SSR -SSR
+SSR -SSR
~
GND
GND
+SSR -SSR
~
2
~
~
2
0-10V
GND
0-10V GND
GND
0-10V
32
33
25 26 27 28 29
34
35 36 37 38 39 40 41 42 43
30
31
32
33
34
35 36 37 38 39 40 41 42 43
44 45 46 47 48 49 50
32
33
34
35 36 37 38 39 40 41 42 43
44 45 46 47 48 49 50
SWO
SWO
DATA
DATA
72 71
68 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51
70 69
PRESENCE
PRESENCE
RUN
COOL/HEAT
REC ERR
DEFROST EXTERNAL
DEFROST EXTERNAL
REC ERR
ERROR
DEFROST EXTERNAL
FIRE
BOOST
FIRE
BOOST
SENSOR
SENSOR
OUTPUT
HEAT PUMP
HEAT PUMP
ON/OFF
ON/OFF
ON/OFF
PIR
PIR
CONTACT
CONTACT
EXTERNAL
CONTACT
EXTERNAL
EXTERNAL
CONTACT
CONTACT
FIRE
FIRE
CONTROL
CONTROL
CONTROL
EXTERNE
EXTERNE
EXTERNE
OUTPUT
INCENDIE
INCENDIE
BOOST
ON/OFF
ON/OFF
BOOST
ON/OFF
72 71
3
4
5 6
7
8
62 61
63 64
63 64
62 61
63 64
57 58
57 58
BOOST
BOOST
4
5
6
DX = ON/OFF
7
11
12
11
13
11
12
13
Commande
Commande
Commande
CMSI
CMSI
exterieure)
á distance
á distance
á distance
68 67
66 65
66 65
66 65
defrost
!
defrost
defrost
2VV.Creating innovative solutions for you and your business since 1995.
DX DEFROST
DX GENERAL ERROR
DX DEFROST
10
10
10
9
(settable)
(settable)
(settable)
(settable)
PRESENCE
CAPTEUR
S
1
2
3
4
5
6
GTC
GTC
ou
ou
or
Control panel
or
Control panel
Control panel
boitier de commande
boitier de commande
boitier de commande
7
ModBUS RTU via
8
ModBUS RTU via
Rs485
Rs485
19
49 50
EXT. SENSOR
3
Capteur Externe.
(two-wire shielded cable)
Câble deux fils blindé
J1/J2
J1/J2
J1/J2
T-WATER T-WATER T-ROOM
T-WATER T-WATER T-ROOM
T-WATER T-WATER T-ROOM
-OUT
-IN
-OUT
-IN
-OUT
-IN
FILTER
FILTER
9
9
10
10
JP1
JP1
INT
INT
LED1
LED1
44 45 46 47 48 49 50
SWO
DATA
1
1
1
2
2
2
PRESENCE
IN GND
IN GND
REC ERR
IN GND
FIRE
BOOST
15VAC
15VAC
15VAC
SENSOR
CO2/RH/EXT
CO2/RH/EXT
CO2/RH/EXT
PIR
CONTACT
FIRE
CONTACT
CONTACT
CONTACT
ERROR
ERROR
ERROR
INCENDIE
CONTACT
CONTACT
ERREUR
ERREUR
CONTACT
ERREUR
BOOST
9
10
11
62 61
59 60
59 60
59 60
57 58
BOOST
7
!
!
14
14
12
14
13
CMSI
CAPTEUR 0-10V
SENSOR
CO
CO
/ RH/VOC
/ RH/VOC
CAPTEUR 0-10V
SENSOR
CO
/ RH/VOC
2
2
2
16
16
15
15
15
EXTERNAL
EXTERNAL
EXTERNAL
51 52
51 52
53 54
53 54
53 54
2
1
2
2
1
V
VCS-R4-SU-*-
in control module
in Steuermodul
24V
GND
0-10V
24V
GND
HEAT
0-10V
Sensor LPHW (incluido)
Conexión para la unidad SLAVE
Protección contra heladas (NC)
Control externo - (entrada, ON / OFF)
Termostato (entrada, NO / NC)
Contacto de PUERTA (entrada, NO / NC)
GTC
ou
or
Señal de control de la unidad MASTER
ModBUS RTU via
Servo control de la válvula de agua 0-10V
Rs485
FILTER
9
10
JP1
INT
LED1
!
CAPTEUR 0-10V
SENSOR
16
51 52
1
8
5