RIB K4W10 Manual Del Usuario página 32

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

G G
B B
follows from page 31
O
PERATION OF THE OPERATING ACCESSORIES
O
PENING BUTTON (COM-OPEN) with timer function
T
IMER FUNCTION OF THE OPENING BUTTON
APPLICATIONS
C
LOSING BUTTON (COM-CLOSE)
J
OGGING OPERATION BUTTON (COM-K BUTTON)
DIP5 - OFF =>
DIP5 - ON =>
R
ADIO TRANSMITTER
DIP4 - OFF =>
DIP4 - ON =>
A
UTOMATIC CLOSING FOR COMPLETE OR PEDESTRIAN
OPENING
O
PERATION AFTER BLACK-OUT
S
AFETY ACCESSORIES OPERATION
S
AFETY ENCODER (only for K PLUS)
It must act as a security in opening and closing, with movement
inversion in case of collision.
DIP 7 (ON) operates the motor with encoder.
The buzzer sound to for 5 minutes, to indicate the state of
alarm, and the blinker blinks for 1 minute.
P
HOTOCELL 1 (COM-PHOT 1))
DIP 6 - OFF =>
DIP 6 - ON =>
S
TOP BUTTON (COM-STOP)
The STOP button stops the gate during any operation.
B
LINKER
N.B.: This electric board can supply power ONLY TO BLINKERS
WITH (Code ACG7059) BLINKING CIRCUIT, with max. 40W
lamps.
PRE-BLINKING FUNCTION:
- With DIP8 on OFF
- With DIP 8 on ON
B
UZZER (Optional) - PAY ATTENTION TO THE POLARITY -
The buzzer emits an intermittent sound signal during opening and
closing cycles. When safety devices are operated (alarm), the
intermittence frequency of this sound signal Increases.
W
ARNING LIGHT OF GATE OPEN (COM-SIGNAL)
N.B.:
If you overuse the push button panels or the lamps, the
control board logic system may be compromised,
resulting into a possible operation block.
Tabla de contenido
loading

Tabla de contenido