Operation; Preparation For Measurement; Ac Voltage Measurements - Greenlee 6711 Manual De Instrucciones, Servicio Tecnico Y Recambios

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

OPERATION

PREPARATION FOR MEASUREMENT

WARNING
• Visually examine the tester for external damage before each use.
• Do not use tester if wet or damaged.
Electric shock or damage to tester may result.
1. Check the tester for external damage caused by transport or improper use. Do not use tester if wet or
damaged.
2. Replace or repair tester if:
• The tester shows obvious damage.
• The tester does not carry out the desired measurements.
• The tester has been stored for too long under conditions in excess of those listed in the Specifications
section.
• The tester has a discharged or missing battery.
3. Check the Battery
Touch the test probes together. If no sound is audible, the batteries must be replaced. Follow the
Maintenance instructions for Battery Replacement.
Note: Voltage measurements do not require a battery. However, a good battery must be installed in the
tester to perform a Phase Test or a Continuity Check, or the function of the backlight.
Note: Always test on a known live circuit prior to use.

AC VOLTAGE MEASUREMENTS

DANGER
• Contact with live circuits can cause serious injury or death.
WARNING
• Do not touch probe ends while testing live circuits.
• Do not exceed rated voltages.
Electric shock or damage to tester may result.
CAUTION
• The tester has a built-in load, therefore, the operation and recovery time is specified as follows:
Voltage Range
9 ... 50V
50 ... 300 V
300 ... 700 V
Please note that the recovery time depends on the ambient temperature.
1. Unsnap the Secondary Test Probe from the tester.
2. Touch both test probe tips to the circuit under test. The tester switches on automatically for voltages
greater than 15 to 20 VAC. The voltage and an "AC" will be displayed. The buzzer will sound. For accurate
measurements when measuring voltages less than 15 to 20 V, the "Voltage-Test" button must be pressed.
Note: In order to avoid tripping a GFCI when performing a voltage test between Line and Ground, first test
between Line and Neutral, then perform the Line to Ground measurement.
6
All manuals and user guides at all-guides.com
Operating Time
continuous use
approx. 10 minutes
approx. 30 seconds
6711 Digital Voltage Tester
Required Recovery Time
N/A
10 minutes
10 minutes
Tabla de contenido
loading

Tabla de contenido