Disconnect Power to the Terminal
1. Disconnect power at the source and remove the power cord from the
PanelView terminal.
2. Disconnect all communication cables from the terminal.
ATTENTION
Remove the Existing Terminal
1. Remove the mounting clips that secure the terminal in the panel.
TIP
2. Slide the existing terminal out from panel.
Attach the Adapter Plates to the Panel
The studs on the front adapter plate fit within the cutout of the terminal.
1. Place the front adapter plate into the panel cutout until the sealing gasket
material is firmly against the front of the panel.
Adapter Kit for PanelView Standard and PanelView "e" Terminal Cutouts
Make sure the power cord of the terminal is disconnected and that all cables
have been disconnected from the terminal.
The PanelView Standard and PanelView "e" mounting clips are different than
the PanelView Plus mounting clips. Store the mounting clips separately to
avoid confusion later.
Publication 2711P-IN010C-MU-P - March 2007
5