SETTING THE TEMPERATURE OFFSET
. This setting compensates for any difference (offset) between the tem-
perature displayed by the unit and ambient temperature measured in the
room. This difference varies from one room to another as it depends on the
insulation, room layout and location of the appliance.
. This difference must be closed when the ambient temperature is stabilised
after more than 2 hours of heating in Comfort or Eco mode.
. This setting changes neither the stability nor the accuracy of the tempera-
ture regulation.
- Press MENU, then + to access the OFFSt menu.
- Press OK-boost to enter this menu.
- Press + or - to set the offset between 8°C and -8°C
- Press OK-boost to validate the offset.
- Press MENU to exit the menu.
For example, if the appliance is set at 20°C and if the ambient thermometer
displays 18°C, the offset must be -2°C.
For example, if the appliance is set at 20°C and if the ambient thermometer
displays 22°C, the offset must be 2°C.
DEROGATION (Prolonged absence)
. This function maintains frost protection mode at
7.5°C during a prolonged absence then returns to the
initial settings.
- Press MENU, then + to access the dEr menu.
- Press OK-boost to enter this menu.
- Press + or - to select the number of days of absence from 1 to 99 days (for
example, 5 days = 05.d).
The current day must be counted as an absence day.
- Press OK-boost to activate the absence setting; the number of remaining
days is displayed alternately with the setpoint temperature.
The initial mode (Comfort, Eco or Programme) is re-established at midnight
on the last day of absence.
- Press MENU to cancel the absence function.
For example, if the absence is programmed on Monday for 3 days, the ap-
pliance will remain in frost protection mode until Wednesday at midnight.
16
Quick start