Declaration Of Conformity - Truma APC 310 Instrucciones De Uso Instrucciones De Montaje

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 40
Troubleshooting
Error
The battery does not charge. Check all connections from
The maximum charging
current is not reached.
The master switch does not
react.
LED flashes* 1 x
Battery not connected or
defective.
LED flashes* 2 x
Unit is getting too hot.
LED flashes* 3 x
Battery temperature
too high > 50 °C.
LED flashes** 4 x
Defective wiring.
Temperature sensor or cable
defective.
LED flashes 5 x
Battery voltage of 15.4 V
and / or the max. output
current exceeded three
times.
* Reset the flash code:
takes place automatically after addressing the cause.
** Reset the flash code:
disconnect the mains voltage after addressing the cause
and disconnect battery (approx. 1 minute).
Flashing frequency:
0.2 s on, 0.2 s off, period between the flashing sequence 2 s.
If this does not solve the problem, please contact the
Truma Service.
Rectification
the device to the battery, en-
sure that they are connected
to the right terminals. Check
all fuses and the mains sup-
ply connection.
The device is too warm,
ensure better ventilation of
the device.
Disconnect the device from
the mains supply! Pull out
the mains plug and discon-
nect the battery. Reconnect
the battery after 15 seconds
and reconnect the device to
the mains supply. Press the
master switch again.
Connect battery, or replace
battery if necessary.
Ensure there is sufficient
ventilation.
Ensure there is sufficient
ventilation.
Address defect in wiring.
Replace temperature sensor.
Resetting the blink code:
Disconnect mains voltage
and disconnect battery
(approx. 1 min.).
In the event of repeated oc-
currences: Please contact
the Truma Service.

Declaration of conformity

1. Information about the manufacturer
Name:
Truma Gerätetechnik GmbH & Co. KG
Address: Wernher-von-Braun-Str. 12, D-85640 Putzbrunn
2. Device identification
Type / model:
APC 310
3. Meets the requirements of the following EC Directives
3.1 Electromagnetic Compatibility 2004/108/EC
3.2 Low Voltage Directive 2006/95/EC
and bears the CE symbol.
4. Basis of the conformity assessment
EN 61000-6-1:2007; EN 61000-6-3:2007; EN 60335-1:2009;
EN 60335-2-29:2005
5. Information and the function of the signatory
Signature: Dr. Andreas Schmoll
Managing Director / Engineering
Putzbrunn, 11.05.2011
13
Tabla de contenido
loading

Tabla de contenido