1 Pressure regulation valve
2 Concentrate regulation valve
3 Flow meter for concentrate
4 Media filter (only WPC 100 FW-AM)
5 Fine filter
6 Manometer for output pressure of
fine filter
7 Manometer for inlet pressure of fine
filter
8 Manometre for pump pressure
9 Flow meter for drinking water
10 Manometer for concentrate pres-
sure
11 Control board
12 Control for Media filter (only WPC
100 FW-AM)
13 Manometer for inlet pressure of me-
dia filter (only WPC 100 FW-AM)
14 Indicator lamp - Appliance Ready
15 Indicator lamp - Operation
16 Indicator lamp - fault
17 Main switch
18 Active carbon filter
19 Membrane filter unit

Start up

Danger
Risk of injury if the plant is not installed
properly. Risk to health on account of
poorly treated drinking water. The
plant may be put into operation only
when set-up, installed and prepared for
operation by skilled and authorized

Operating elements

personnel according to service manual
5.906-413.0.

Before Commissioning

Check the connection of the plant to
the raw water source.
Ensure uninterrupted flow of the
generated drinking water into a tank
or a suitable user-side facility.
Note
The drinking water must be able to flow
out without any counter-pressure. The
height difference must not be more
than 3 m.
Filling up the dosing station
Note
If the plant is fitted with one or more
dosing stations, then it needs to be en-
sured that this has been connected
properly and filled up.
Fill up dosing station (refer chapter
"Maintenance and Care/ Mainte-
nance jobs")

Operation

Switching on the plant
Check whether the mains plug of
the dosing pumps and the media fil-
ter (only WPC 100 FW-AM) are
connected to the power supply.
Turn the main switch to position "1"
Monitoring elements
1 Indicator lamp - Operation
Glows when drinking water is being
produced.
2 Indicator lamp - fault
Glows or blinks when there are in-
terruptions
3 Indicator lamp - Appliance Ready
Glows when the plant is switched
on and when the drinking water tank
is full.
Switching off the plant
Warning
Risk of damage. If the plant is to be
shut down for more than 14 days, then
Kärcher Customer Service must carry
out some preservative tasks.
Turn the main switch to position "0"
Note
Do not switch off WPC 100 FW-AM
overnight! The media filter is automati-
cally cleaned during the night. There is
English
5
Tabla de contenido
loading

Este manual también es adecuado para:

Wpc 100 fw-aWpc 100 fw-am

Tabla de contenido