MOTOR OY4"
Model
OY4" 050
OY4" 075
OY4" 100
OY4" 150
OY4" 200
OY4" 300
OY4" 050
OY4" 075
OY4" 100
OY4" 150
OY4" 200
OY4" 300
OY4" 400
OY4" 550
OY4" 750
OY4"1000
OY4" 050
OY4" 075
OY4" 100
OY4" 150
OY4" 200
OY4" 300
OY4" 400
OY4" 550
OY4" 750
OY4"1000
Splicing the drop cable to the motor cable must be carried out through suitable resin filled kit, following the
producer's instructions and do not forget to join the core cable with the same colour (black-blue-red).
INSTALLATION
Normal working position of the OY4" series motor is vertical. Drop cable must be secured to the riser pipe at
intervals no longer than 1.5 m Motor must be positioned, for a correct cooling, at a distance of about 1 m to the
well bottom to avoid accumulation of sand and mud.
Hp
kW
4x1
0.5
0.37
50
0.75 0.55
38
1
0.75
30
1.5
1.1
22
2
1.5
3
2.2
0.5
0.37
240
0.75 0.55
164
1
0.75
133
1.5
1.1
97
2
1.5
72
3
2.2
51
4
3
41
5.5
4
31
7.5
5.5
10
7.5
0.5
0.37
90
0.75 0.55
60
1
0.75
47
1.5
1.1
35
2
1.5
26
3
2.2
4
3
5.5
4
7.5
5.5
10
7.5
Drop cable section mmq
4x1.5 4x2.5
4x4
75
125
57
95
152
45
75
120
33
53
85
23
38
63
28
45
246
200
333
146
244
390
109
180
290
78
130
207
62
104
167
46
77
124
33
56
90
66
135
90
150
240
71
118
190
52
87
140
40
66
106
29
48
76
37
60
27
44
32
4x6
4x10
4x16
174
127
210
92
154
246
67
112
180
435
310
516
250
416
186
310
496
135
225
360
100
165
270
210
160
266
115
191
306
90
150
240
66
110
176
48
80
128
35
58
96