Step 7 Connect one end of the AC power cord to the SR4-WBS2's power socket and the
English
other end to a wall socket. Then power on the unit.
Deutsch
Step 8 Wait for the system to complete initialization as the hard drive status indicator will
briefly light up in red and blue interchangeably and then stop. When your computer
has booted, your operating system should recognize the RAID volume automatically.
Français
After the volume has been successfully recognized, please follow the formatting of
hard drive instructions given by the operating system to format the drive volume of
Español
your preference. Once the formatting has been completed, the RAID system is
ready for use.
中文

5. Replacement of Malfunctioning Drive and Data Rebuild Instructions

日本語
When a front hard drive indicator has lit up red and the audio alarm sounds, this could mean
the indicated hard drive may be malfunctioning. If this occurs, you may press the mute button
at the rear of the system to shut off the audio alarm and power off the system immediately if
한국어
in the allowed operational state, and then re-power on the system to double check and see if
in fact the indicated hard drive has malfunctioned. If the problem persists, please turn off the
system and follow the directions below :
Step 1 Remove the drive tray containing the malfunctioned hard drive and disassemble
the hard drive from drive tray.
Step 2 Mount the new hard drive onto the tray and insert it back to the empty drive position
of the SR4-WBS2, then push the latch into place making sure it is secured and locked.
Step 3 In RAID 5 mode, when you turn the system on, the hard drive status indicator of the
replacement drive will interchangeably blink red and purple to inform that the data is
being rebuilt to the replacement drive. During data rebuild, you may operate the SR4-
WBS2 as normal. When the indicator stops, the data rebuild process has been
completed.
In RAID 0 mode, since all data have been destroyed or lost due to hard drive malfuntion,
you are required to re-format the drives for use.

6. System Temperature Overheat and Fan Failure Management

If the alarm indicator has lit up red and the audio alarm sounds, this could mean that either a
system fan has stopped operating entirely or the system temperature has exceeded over the
default temperature of 60°C. When this occurs, you may press the mute button at the rear of
the system to shut off the audio alarm and power off the system immediately if in the allowed
operational state to let the system cool. Check and see if the overall operation environment is
well ventilated and make sure there are no blockages to the enclosed fan and then re-power
on the system to continue use. If the problem persists, please turn off the system and contact
your supplier or the STARDOM tech support for further assistance.