1.3 - Lock the Device on its Wall Bracket
- Place the device on bracket S as shown. - Move the device towards the bracket
then lift (arrows 1 and 2).
- Insert the bracket fl anges in the holes on the device and lower (arrow 3).
- Lock by turning the two latches (V) half a turn, your device is locked.
Power (W)
Overall Length
Height (mm)
Thickness (mm)
Device Weight (kg)
1.4 - Connect the Radiator
The device must have a 230V 50 Hz power supply.
Radiator power must be directly connected to the grid after the
all-pole circuit breaker with an opening contact distance of at
least 3 mm without an intervening switch (clock, mechanical
and static relay, ambient thermostat, etc...).
The electrical connection uses 3-wire cable (brown = phase,
blue = neutral, black = pilot wire) through the connection box.
In damp environments such as kitchens, the connection box
must be at least 25 cm from the ground.
The installation must have a protection device such as a
circuit breaker.
Connecting to ground is forbidden. Do not connect the pilot wire (black) to ground.
If the power cable is damaged, it must be replaced by the manufacturer, after sales service, or any similarly
qualified person in order to avoid danger.
If the pilot or piloted device is protected by a 30mA differential (for example: bathroom), the pilot wire power
supply must be protected on this differential.
Pilot Wire Connection Test
You may connect the pilot wire if your house has a scheduler or energy manager.
In this case, to check that the scheduling orders are correctly transmitted, conduct the following checks:
Orders
No
Received
power
Signal to
transmit
Mode Obtained
COMFORT
For scheduling through the pilot wire or carrier power, freeze protection and load shedding orders have priority.
The delay for switching over from comfort mode to eco mode is about 12 seconds.
2 - Controls
Screen
and
keys
and
keys
OK/Validate
- Stop heating
Menu keys
Ventilation function/Windows open
Energy saving opération
431396J_maradja_international.indd 12
Horizontal Model
750
1000
1250
491
639
787
615
147
16
20,8
26,2
230V for 3s
COMFORT -1°C COMFORT -2°C
1500
2000
935
1157
29
37,8
230V for 7s
230V
ECO
-115V negative +115V positive
LOAD
FREEZE
SHEDDING
PROTECTION
HEATING STOP
11/06/10 11:10
2.1
3 -
Wh
Sta
Act
stan
4 -
Wh
Set
Exit