WET CONDUIT INSTALLATION
4.
With the MicroBrite light in your hands, roll the body of the light several turns
counter-clockwise, so that the cord of the MicroBrite light receives several
"pre-twists" in a counter-clockwise direction. Read Step 5 before continuing
with Step 6.
Dry/Sealed Conduit Installation (use provided kit), see page 9: If
5.
code requires an O-Ring to be installed on the light for a dry conduit
installation, install the O-Ring as described on page 9, then continue with
Step 6 below.
BEFORE INSTALLATION
6.
Insert the MicroBrite light into the 1.5" wall fitting. By hand start the process of
threading the male threads on the MicroBrite's white threaded adaptor ring into the
female threads of the wall fitting.
DURING INSTALLATION
By hand turn light clockwise.
Insert adaptor male thread
adaptor ring into female
thread of wall fitting
By hand, turn light body
counter-clockwise to
twist cord
Cord should be twisted
counter-clockwise
Cord will un-twist
as light is turned
clockwise into fitting
(Continued)
MicroBrite Color and White Light Installation and User's Guide
7