A.I.&.E TORONTO RO2716-32Z Manual De Instrucciones página 7

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 61
Installation
Please be aware: that no products should be sealed against the wall/opening as
this can effect the performance of the heater unit.
Minimum Installation Height:
From floor level to bottom edge of product, Minimum 300mm.
This suite is supplied with a wall fixing Bracket. The suite can be installed
at any height as long as it is not below the recommended 300mm. (Please
note the 700mm measurement is given as a common installation height). The
recommended installation height is a minimum of 300mm from the floor level to
the underside of the hearth.
Warning: Installing this product below 300mm will
cause overheating issues.
The suite is designed as a wall mounted suite; it is
not suitable to be installed at floor level.
Installation:
This model is provided with a wall mounting bracket along with x3 screws and
wall plugs.
PLEASE NOTE: The screws and plugs provided are only suitable for a solid wall
fixing. If the installation is onto a hollow/stud wall, we recommend that heavy
duty wall anchors or equivalent are used.