CONTACT
27(ST)
26(COM)
29 (ANT)
30
32(ORO)
31(COM) Clock timer contact input (N.O.).
33(AP)
37(COM) Open control signal input (N.O.).
34(CH)
37(COM) Close command input (N.O.).
35(PP)
37(COM) Step by step mode command input (N.O.).
36(PED)
37(COM) Partial open control signal input (N.O.).
ABSOLUTE ENCODER
(SMARTY EMA)
RECEIVER CARD
BATTERY CHARGER
B71/BCHP
BATTERY KIT
2x12 Vdc 4,5 Ah
(B71/BCHP/EXT)
Only AGM type
DESCRIPTION
STOP command input (N.C. or 8.2 kOhm).
The current manoeuvre is arrested if the safety contact opens.
N.B.: the controller is supplied with this contact already jumpered by ROGER TECHNOLOGY.
–
. (normally closed) incoming contact.
N.B.
When the clock function is active, the gate opens and remains open.
At the end of the programmed time set with the external device (clock), the gate closes.
IMPORTANT
matic reclosure time count is resumed when the opening command is released.
The function of the control is determined by parameter
On double leaf gate automation systems, by default, the partial opening command opens LEAF 1
completely.
With single leaf swing gate installations, by default, partial opening is 50% of total opening.
Absolute encoder installed on SMARTY Series motors. Its installation (which is a factory standard for
reversible SMARTY motors) makes it impossible to use SMARTY motors to open the door outwards
During travel acquisition, the encoder reading is acquired in the completely open and completely
closed positions. During normal operation, the encoder reading is acquired at each motor start, except
in the case of direction inversion due to activation of the sensing edge, the obstacle detection system
or the photocells, or requested by the user with a command.
N.B.
emit a short audible signal (whistle). If no audible signal is heard, the encoder may be disconnected,
absent or damaged.
For SMARTY REVERSIBLE
TECHNOLOGY. The reading of the position by absolute encoder, only when the door is completely
closed or open, is preceded by a slow rotation of the motor (duration 1 second) which discharges the
mechanical voltage from the reduction before starting the manoeuvre. This ensures a softer start and
eliminates any noise.
For SMARTY IRREVERSIBLE
the motor.
Enable the encoder with the parameter
IMPORTANT
parameter
. An incorrect setting will prevent the absolute encoder from working.
If parameter
– PR1
– PR2
(Fig. 7) IIn the absence of mains voltage, the central network gets powered by the batteries, the display
shows
red or until the battery voltage drops below the minimum permissible limit. In this case,
Low) is shown on the display and the control unit accepts no commands.
If mains power is lost while the gate is moving, the gate stops and then automatically resumes the
interrupted manoeuvre after 2 seconds.
parameters
and
.
To reduce battery consumption, the positive power feed wire of the photocell transmitters and receiver
may be connected to terminal SC
unit disconnects power from the accessory devices when the gate is completely open or completely
closed.
WARNING! the batteries must always be connected to the electronic control unit in order to charge.
Periodically (at least every 6 months), check that the batteries are in good working order.
For more information, refer to the installation manual for the B71/BCHP battery charger.
.
SMARTY/EMA is available for installing the encoder on
and perform the travel acquisition procedure.
SMARTY/EMA installed, repeat the travel acquisition procedure
).
or
).
(Battery
59