1
POWER IN
IP65 power input socket with rubber sealing cap. Operating voltage 100 - 240 V AC / 50 - 60 Hz. Connection via supplied power cable
(when not in use, always close with rubber sealing cap).
2
POWER OUT
IP65 power output socket with rubber sealing cap. Facilitates power supply to other CAMEO lights. Ensure that the total current consumption of all
connected devices does not exceed the value specified on the device in amperes (A) (when not in use, always close with the rubber sealing cap).
3
STANDBY SWITCH
Ensure that the battery is charged sufficiently or connect the lights correctly to the power supply. Move the switch to the down position to
make the floodlight ready for operation. During the start-up process, "Welcome to Cameo", the model name and the software version will
be shown consecutively on the display. When the switch is not in the down position, the floodlight is in standby mode. In both operating
states, the battery is constantly being charged, as long as the floodlight is connected to the power supply correctly.
4
DMX IN
Male IP65 5-pin XLR socket for connecting a DMX control device (e.g. DMX console. When not in use, always close with the rubber sealing cap).
5
DMX OUT
Female IP65 5-pin XLR socket for sending DMX control signal (when not in use, always close with the rubber sealing cap).
6
OLED DISPLAY
Shows current operating mode, charging status of the battery and the menu items in the edit menu.
7
TOUCH-SENSITIVE CONTROLS
MODE – Press mode to access the selection menu for system settings. Press repeatedly to go back to the main display.
ENTER – Press ENTER to access the menu levels to make value changes, and to access the sub-menus. Confirm value changes by
pressing ENTER.
UP and DOWN – Select individual menu items in the selection menu (DMX address, operating mode etc.) and in the sub-menus. Allow changes to
the value of a menu item, such as the DMX address as required.
8
EYELET FOR SECURING CABLE
Overhead installation must only be carried out by qualified personnel. A suitable safety cable must be fitted to the floodlight's eyelet to
ensure that it does not fall down.
9
PRESSURE EQUALISATION ELEMENT
Pressure equalisation element to prevent condensation inside the housing. In order to ensure its proper function, the element must be
protected from contamination.
TIPS: In order to provide protection from spraying water, in accordance with protection class IP65, special IP65-rated XLR connectors must
be used correctly with the DMX input and output sockets, or they must be closed using the rubber sealing caps. When connected correctly,
or when sealed correctly with the rubber sealing caps, the POWER IN and POWER OUT sockets are protected from spraying water according
to IP65.
6