The equipment does not have a general emergency stop on the control panel. This is
to avoid a possible accident due to not removing waste heat in the reactivation flow. To
stop in a situation of imminent risk or accident, use the I1 isolator identified in red and
yellow and set it to position 0.
This should not be used to for a normal stop of the equipment.
Electrical components
Work affecting electrical components must be carried out by qualified electricians.
Use only original class fuses with correct calibration.
Perform regular checkups on the electrical equipment.
Defects, such as loose connections or burnt cables, should be repaired immediately.
User Manual DFRA Series | 11