Baxi PBM-i 20 Manual Del Usuario página 126

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

OPERATION AND FUNCTIONS OF THE ROOM CONTROLLER
Programming the time bands
The room controller can customise on/off times for each zone in the system, based on six time bands.
The six time bands are identified by the following symbols, selected by turning the knob:
Time band 1
Time band 2
The time bands on systems with multiple zones, each of which is managed by its own room controller (maximum 6), must be
programmed on each room controller.
For installations with heap pump connected directly to the system, without storage tanks and secondary pumps, parame-
ter 011D must be set to 0. This means that heat pump operation will be managed based on the time bands.
1
x5 sec.
• Press the
button for 5 seconds
The time bands can be programmed by selecting the days in preset groups or for each individual day.
4
A
GROUP OF 7 DAYS
A Turn the knob
B Press the knob to confirm
8
Time band 1
• Press the knob to confirm
46
PBM 20÷40 EN
Time band 3
2
• Turn the knob
5
A
B
GROUP OF 5 DAYS
A Turn the knob
B Press the knob to confirm
9
A
Time band 1 start hours
A Turn the knob
B Press the knob to confirm the
hour value
Time band 4
Time band 5
6
A
B
GROUP OF 2 DAYS
A Turn the knob
B Press the knob to confirm
10
A
B
Time band 1 start minutes
A Turn the knob
B Press the knob to confirm the
minutes value
Time band 6
3
• Press to confirm
7
A
B
INDIVIDUAL DAY
A Turn the knob
B Press the knob to confirm
11
A
B
Time band 1 room temp. set point
A Turn the knob
B Press the knob to confirm
A
B
B
Tabla de contenido
loading

Este manual también es adecuado para:

Pbm-i 30Pbm-i 40

Tabla de contenido