INSTALLER CONNECTIONS
A5 room controller connection
Installation instructions
The room controller must be installed in the best reference
position for temperature control.
Position the room controller as follows:
• around 1.5 metres from the floor, in a part of the room that
allows the sensor to accurately measure the room temper-
ature;
• away from cold air flows, sunlight or other sources of heat.
• leave enough space above the room controller to allow
assembly and removal where necessary.
• If the room controller is removed from its base, it discon-
nects from the power supply and consequently is no
longer operating.
Installation procedure
Assembly
• Separate the front from the rear of the terminal using a
screwdriver r (1)
• Disconnect the 4-pin connector from the front part (2)
• Remove the cover A1, unscrewing the screw A2 (3).
• Fix the controller support to the wall using the holes A3
(4). Support hole size and spacing in figure (5).
• Make the electrical connections as shown in the figure (6),
also see the wiring diagram.
3
A1
A2
6
Number of wires
Minimum power cable cross-section
Maximum distance
20
PBM 20÷40 EN
4
A3
A5 room controller terminal block
5 shielded
0,5 mmq
500 m
1
5
A3
I A
min.
10 cm
2
131
83,5
E
Installer terminal block
51 52 53 54 55