2.3 Safety devices

The unit is equipped with the following safety devices to prevent hazards to persons and objects:
Switch
Temperature limiter in the heating
element
Red LED display on the control unit
Safety valve 5 bar (included)
Automatic bleeder valve 3/8" (flow
pipe)
Automatic bleeder valve 3/8" (included)

3. Description

3.1 Intended use

Caution!
The circulation pump is used exclusively for tempering and circulating supply water for drinking bowls in stables. The circulation
pump circulates the water within a ring pipe. The integrated heating element prevents the water from cooling down and freezing
in a ring pipe. Chemical additives and acidification of the supply water can irreparably damage the unit.

3.2 Technical data

Model
Type:
Output:
Electrical connection:
Protection class:
Water connection output:
Water connection inlet:
Water pressure: max. 5 bar
Dimensions:
Weight:
Heating element
Output:
Protection type:
Temperature controller (TR):
Factory setting (TR):
Safety temperature limiter (STB):
Circulating pump
Output:
Protection type:
Ambient temperature +25 °C:
Max. operating pressure:

3.3 Conversions or modifications

In the event of unauthorised conversions and modifications to the unit, any liability and warranty on the part of the manufacturer will be rendered void.
Conversions and modifications may only be carried out with the written consent of the manufacturer.
In switch position 0, the circulation pump and the heating element are switched off.
The temperature limiter STB serves as a switch-off safety device in the event of a failure of the
temperature controller.
The LED lamp lights up when the temperature controller switches on the heating element and
the water is heated.
The safety valve is used to control the pressure on heat generators in closed systems. When the
set pressure is reached, the valve opens and prevents dangerous limit values from being excee-
ded by releasing the pressure.
The quick exhaust valve is used to completely vent the flow pipe. Remaining air pockets can
permanently damage the heating element.
The enclosed bleeder valve must be installed at the highest point of the entire piping system in
a permanently frost-proof area in a vertical position.
Circulation pump
C10
3050 W
230 V / L1 / N / PE / 50 Hz
IP X4D
1 inch
1 inch
L 520 x W 410 x H 285 mm
6.7 kg
3000 W
IP 54
5 - 35 °C
5 °C on, 15 °C off
95 °C - 8 K
50 W
IP X4D
0 °C to +70 °C
10 bar (1000 kPa)
35