Data Hold
2100-Beta: only voltage
measurement (12...690V AC/DC)
2100-Gamma: voltage and resistance
measurement, Non contact cable
break detector / EF
Measurement Area Illumination / Torch Light
White LED
Backlight
White LED
General Specifications
Operation time
30 s
(DT)
Recovery time
240 s
Operating
-15°C to +55°C
temperature
Storage
-15°C to +55°C
temperature
Humidity
Max. 95% RH
Operating
Up to 2000 m
altitude
CAT IV / 600V, CAT III / 690V
Safety rating
(2100-Alpha / 2100-Beta)
(overvoltage
CAT IV / 600V, CAT III / 1000V
category)
(2100-Gamma)
Pollution degree
2
Protection
IP 64
degree
IEC 61243-3:2014,
Safety
EN 61243-3:2014,
regulations
DIN VDE 0682-401:2015
Approvals,
GS mark from TÜV Rheinland, CE
compliance
Power Supply
Battery 2 x 1.5V (AAA/ IEC LR03)
Power
Approximately 90 mA
consumption
More than 10000 measurements
Battery lifetime
(<5 s / per measurement)
Dimensions
Approximately 280 x 78 x 35 mm
(HxWxD)
(11.0 x 3.1 x 1.4 in)
Weight
Approximately 320 g (0.71 lb)

MAINTENANCE AND REPAIR

According to the operating instructions the voltage
tester do not require any special maintenance for
operation. However, if a malfunction occurs during
operation, the measurement has to be stopped and a
further measurement is not allowed. The unit has to be
tested at our factory service department. Except for the
replacement of the battery, any repair of the instrument
should be performed only by an Authorized Service Center
or by other qualified instrument service personnel.
W
If the instrument is not used for a prolonged period,
the batteries must be removed, as leaking batteries may
be hazardous and cause damages.