Initialization Setting; Status - Samsung SPD-3000 Manual Del Usuario

Ocultar thumbs Ver también para SPD-3000:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Functional Description
OUT1 OFF/OUT2 OFF : If you want to cancel the operating Alarm outputs at once,
select the corresponding menu to cancel the operating Alarm.
MD Dwell Time : When the Motion Detection function is on, the motion of
intruders can be detected. When the motion is detected, the
Alarm signal is displayed in the Alarm Output Terminal. For
detailed settings of the Motion Detection for each Preset menu,
see page 43 and 44.
Alarm Setting
Alarm Enable
ON
Alarm Input
Alarm Output
MD Dwell Time
OFF
ON/OFF : It can be set up how long the operation will be kept when the motion is
detected. (1-59 sec, 1-59 min)

6) Initialization Setting

Initialization Menu
Main Menu
Camera Setting
Sequence Setting
P/T Setting
OSD Setting
Alarm Setting
Initialize

Status

Power On Reset : Camera is initialized into the original status of power input.
Factory Default Settings : Camera is initialized into the factory default settings.
Data including Preset is deleted. This function is used
for initialization all settings.
56
SPEED DOME CAMERA
All manuals and user guides at all-guides.com
Alarm Setting
Alarm Enable
ON
Alarm Input
Alarm Output
MD Dwell Time
ON 30 SEC
Initialize
Power ON Reset
Factory Default Set
Camera Default Set
Auto Refresh OFF
Initial Position
User's Manual
Camera Default Settings: If only the camera module is replaced due to camera
module failure, the new camera module can be set up
with the settings of the old camera module.
Auto Refresh : The electric circuit and the status of the equipment parts within
the camera are optimized regularly. (The cycle can be set up.) If
camera faces toward a certain source of light or if the settings
cannot be kept because of the long time rotation filming of a certain
area, the Auto Refresh function is used to maintain and re-set the
existing camera settings. Default setting is OFF.
OFF, 1-7 Days : This function is disabled in the OFF mode. 1-7 Days enables the
Auto Refresh operation in the interval of the selected days. Auto
Refresh takes less than 10 seconds. The message "Auto Refresh"
disappears after finishing the operation.
Initial Position : If you want to set the default direction of the camera so that the
camera faces that direction when the power is turned on, you
can set up the desired Pan and Tilt for the camera.
7) Status
The status of dome camera setting is displayed.
Main Menu
Camera Setting
Sequence Setting
P/T Setting
OSD Setting
Alarm Setting
Initialize
Status
Cam Model = 30NC
Cam Version = 03.06
Dome Version = 00.01
Dome ID=001
Controller=Duplex-9600
SPEED DOME CAMERA
Camera Status
CAM MODEL
= 30NC
CAM VERSION
= 03.06
DOME VERSION = 00.18
CON PROTOCOL = SAMSUNG TW
DOME ID
= 001
CONTROLLER
= Duplex-9600
Camera Model
Camera S/W Version
Control Board S/W Version
Dome Camera ID
Communication Mode Setup