INSTALL DUCTWORK

Install 6" diameter insulated duct
from the round inlet collar of the unit
to the intake hood and from the oval
outlet of the unit to either the return
side of the HVAC system ductwork, or
to a mechanical closet.
CAUTION
Freezing temperatures can
cause pipes to rupture. Do not
discharge outdoor air directly
at a pipe or water heater, or any
other item at which unheated
outdoor air should not be
directed.
IMPORTANT: The end of the
insulation must be sealed to
prevent condensation from
forming inside the insulation. If
a plastic zip-tie is used to secure
the insulation to the hood collar,
also tape the end to seal it
against condensation problems.
FIGURE 7 – DUCTING TO RETURN SIDE OF HVAC SYSTEM
FRESH AIR
INTAKE HOOD
WITH SCREEN
FIGURE 6 – DUCTING TO CLOSET
SUPPLY DUCT
FURNACE /AIR
HANDLER
FILTER
RETURN
GRILLE
RETURN MIXING BOX
MODEL 8144NC VENTILATOR
FRESH AIR
INTAKE DUCT
FRESH AIR DUCT
FILTER
FURNACE/AIR HANDLER
AIR FLOW
OUTSIDE WALL
OR OUTSIDE
AIR SHAFT
FRESH AIR
INTAKE HOOD
MODEL 8144NC VENTILATOR
MOUNTED TO WALL
FRESH AIR DISCHARGE TO CLOSET
90-2295
SUPPLY DUCT
90-2295
English 7