WIRING & ELECTRICAL SPECIFICATIONS
ELECTRICAL SHOCK HAZARD: 115-volts may cause serious injury or death from electrical shock. Disconnect and tag electrical service before
starting installation or field-service. Leave electrical service disconnected until installation or field-service is complete.
ELECTRICAL SHOCK HAZARD: An interrupted or broken ground may cause property damage, serious injury or death should an electrical fault
occur. The cabinet must be grounded in accordance with national and local codes.
FIRE HAZARD: Use of improper wire may cause serious injury, property damage or death due to fire. Do not use aluminum wire for electrical
service to the ventilator. Use only copper wire.
Input Voltage: 115 VAC, 60Hz, single-phase
Maximum Operating Current: 0.60 A
The Model 8144NC Fresh Air Ventilator must be hard wired. An electrical disconnect switch can be installed as needed to comply with appropriate
codes or ordinances. The ON/OFF switch on the ventilator interrupts the 115VAC service to the blower of the ventilator, but does not disconnect the
power supply input to the unit.
1. Disconnect electrical service at the fuse or circuit breaker that will be
serving the ventilator.
2. Run electrical service to the ventilator. Install an electrical disconnect
switch located as required by national and local code and label it as
a "MECHANICAL VENTILATION" switch to differentiate it from other
switches. A label is provided inside the ventilator carton. See FIGURE 3.
3. Remove the motor speed adjustment knob and take off the cover by
removing the two retaining screws. Remove the cover insulation to
expose the electrical compartment cover then remove the retaining
screw to take off the electrical compartment cover. See FIGURE 4.
FIGURE 4 – ELECTRICAL COMPARTMENT ACCESS
COVER
MOTOR SPEED
ADJUSTMENT KNOB
COVER RETAINING SCREW
4 English
WARNING
FIGURE 3 – ELECTRICAL SERVICE TO VENTILATOR
VENTILATOR
COVER INSULATION
ELECTRICAL COVER RETAINING SCREW
ELECTRICAL COVER
120 VAC
SERVICE
MECHANICAL VENTILATION
DISCONNECT SWITCH
AIRFLOW TEST PORT
90-2313