filter (only for hoods operating in "Filtration Version").
Note: Run the "RESET FILTRES" command via the remote
control.
Activating/deactivating the filter saturation indicator light
Note: Run the procedure with the hood switched off. The
charcoal filter saturation indicator light is usually deactivated.
If no control is given within maximum 10 sec, the hood
automatically exits this function, at any time, and returns to the
previous state.
Press and hold the B+C keys (Simultaneously) to enter the
setup menu:
Briefly press button C to select the filter to be set up:
Grease filter:Green
Charcoal filter: Red
Briefly press button B to activate (the 2nd LED flashing) or
deactivate (2nd LED off).
Note: the LEDs light up for a limited number of seconds after
which they turn off to indicate that the indicator light has been
activated (or deactivated).
The device can also be used in combination with a
Window sensor KIT (not supplied by the manufacturer).
If the Window sensor KIT is installed (only in the case of use
in EXTRACTOR mode), air extraction will halt every time the
window in the room, on which the KIT is applied, is closed.
• The KIT must be electrically connected to the device by
qualified and specialised technical personnel.
• The KIT must be certified separately in accordance with
the safety standards for the component and its use with
the device. Installation must be carried out in accordance
with current regulations for domestic systems.
PLEASE NOTE:
• the wiring of the KIT to be connected to the device must
be part of a certified safety extra-low voltage (SELV)
circuit.
• the manufacturer of this device declines all liability for
any inconvenience, damage or fires caused by defects
and/or problems associated with the malfunction and/or
incorrect installation of the KIT.
Maintenance
Cleaning
Clean using ONLY a cloth dampened with neutral liquid
DO
NOT
detergent.
INSTRUMENTS. Do not use abrasive products. DO NOT USE
ALCOHOL!
Panel
Fig. 14-17
The panel for perimeter suction should always be left closed
and should only be opened in case of maintenance
interventions (eg cleaning or replacing filters).
Grease filter
Fig. 14-17
Traps cooking grease particles.
This must be cleaned once a month (or when the filter
saturation indication system – if envisaged on the model in
possession – indicates this necessity) using non aggressive
detergents, either by hand or in the dishwasher, which must
be set to a low temperature and a short cycle.
When washed in a dishwasher, the grease filter may discolor
slightly, but this does not affect its filtering capacity.
To remove the grease filter, pull the spring release handle.
Charcoal filter (filter version only)
Fig. 15
It absorbs unpleasant odors caused by cooking.
The activated carbons are incorporated into a ceramic
structure, making them easily and completely accessible by
impurities, thus creating a large absorption surface.
The ceramic activated carbon filters will become saturated
after a more or less prolonged period of use, depending on
the type of cooking and frequency with which the grease filters
are cleaned. These odour filters can be thermally regenerated
every 2/3 months in an oven preheated to 200°C for 45
minutes. Regeneration allows a maximum filter lifespan of 5
years.
Replacing lamps
The hood is equipped with a lighting system based on LED
technology.
The LEDs guarantee an optimum lighting, a duration up to 10
times longer than the traditional lamps and allow to save 90%
electrical energy.
For replacement, contact the technical service.