IMPORTANT CAUTION
In order to guarantee that water is of drinkable quality, it must be chemically drinkable
-
before being treated by UV.
- The UV CINTROPUR is delivered with an ultraviolet bulb installed. The UV bulb is a
low pressure, mercury-vapour bulb, emitting light on the germicidal wavelength of
253.7 nanometres.
- To ensure maximum effectiveness of ultraviolet treatment, we always recommend
- If the water treatment system on your installation comprises several treatment units,
the UV is always installed as the final unit.
- The electrical connection is made via a three-pin plug with earth (ground). Before
connecting the unit, check that the power supply corresponds to the 220 volts 50 Hz
needed by the unit.
- For your safety: the power of the device must be fitted with a differential circuit
breaker with a 30 mA sensibility.When the UV bulb is operating a blue light can be
seen through the drain screw.
- The sterilizer must always be left running, even if no water is being used.
Nevertheless, in the event of a prolonged absence without any water being used
(holidays, absence for longer than a week, etc.) the UV CINTROPUR should be
switched off to avoid overheating of the bowl and the UV bulb.
- When service is resumed, allow the water to run for approximately 1 minute (with the
sterilizer switched on) before any is consumed.
- Frequent Start/Stop operation or operation without any water in the bowl is not
recommended since the lifespan of the UV bulb will be reduced.
- The UV CINTROPUR must only operate with water temperatures between 5°C and
50°C; outside this range the unit may be damaged.
- Do not expose your eyes or skin directly to the UV light of the sterilizer bulb.
- Maintenance is limited to changing the UV bulb once a year on the same date, and to
cleaning the quartz sheath if necessary.
- The new, UV bulb must be perfectly dry before it is fitted to the quartz sheath. Take
great care to ensure that your fingers do not come into contact with the glass of the
bulb.
- The quartz sheath may clog up or show signs of traces of lime scale. Should this
occur, the sheath must be removed and cleaned using dilute acid (hydrochloric acid,
vinegar, lime scale solution). Any product that is used must not be abrasive.