General Information - Bresser 51-01000 Instrucciones De Uso

Biorit microscopio de transmisión
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

General Information

About this Instruction Manual
Please read the safety instructions in this manual carefully. To
avoid damage to the unit and the risk of injury, only use this
product as described in the manual.
Keep the instruction manual handy so that you can easily look
up information on all the functions.
DANGER!
You will find this symbol in front of every section
of text which deals with the risk of severe injury
or even death in the event of improper use.
CAREFUL!
You will find this symbol before every section of
text that deals with the risk of minor to severe
injuries resulting from improper use.
NOTE!
You will find this symbol in front of every section
of text which deals with the risk of damage to
property or the environment.
Intended Use
This product is intended only for private use.
It was developed for the magnified display of things in nature.
General Warning
DANGER!
Tools with sharp edges and points are often used
when working with this device. For this reason, store
this device and all accessories and tools in a location that is
out of the reach of children. There is a RISK OF INJURY!
DANGER!
This device contains electronic components which op-
erate via a power source (power supply and/or batter-
ies). Do not leave children unattended when using the device.
Only use the device as described in the manual, otherwise you
run the RISK of an ELECTRIC SHOCK.
DANGER!
Do not expose the device to high temperatures. Use
only the supplied power adapter. Do not short circuit
the device or batteries, or throw them into a fire. Excessive
heat or improper handling could trigger a short circuit, fires or
even explosions.
DANGER!
Never bend, pinch, pull or run over the power and
connecting cables or extensions/adapters. Protect the
cables from sharp edges and heat. Before operation, check
the device, cables and connections for damage.
Never use a damaged unit or a unit with damaged power ca-
bles, etc. Damaged parts must be exchanged by an author-
ized service centre immediately.
Position your device so that it can be disconnected from the power
supply at any time. The wall socket should always be located near
the device and be easily accessible, since the plug on the power
cord serves as a disconnecting device for the power supply.
DANGER!
Children should only use the device under adult su-
pervision. Keep packaging material (plastic bags, rub-
ber bands, etc.) out of the reach of children! There is a RISK
OF CHOKING!
CAREFUL!
Children must not have access to the included chemi-
cals and liquids. Do not drink the chemicals. Wash
hands thoroughly with running water after use. In the event of
contact with the eyes or mouth, rinse thoroughly with water. In
the event of pain, contact a doctor immediately and take the
substances with you.
NOTE!
Do not disassemble the device. In the event of a defect,
please contact the Service Centre in your country (see the war-
ranty card).
Do not expose the device to temperatures above 40°C.
All parts:
B
Eyepiece
C
Barlow lens
D
MikrOkular
E
Monocular barrel
F
Microscope head
G
Objective revolver
H
Objective
I
Microscope stage
Fig. 4 MikrOkular
Fig. 5 Slide Stage
Fig. 6 Stage adjustment
Fig. 7 Software
Fig. 8 Filter wheel
Fig. 9 Barlow lens and
eyepieces (WF 5x,
WF 10x, WF 16x)
Fig. 10 5 slides, 10 covering
glasses and
20 preparations
1. General/Location
Before you set up the microscope, you must choose a suitable
location. First make sure that your microscope is on a stable
and solid surface.
An electricity supply is required for observation with the elec-
tric illuminator.
2. Electric Illumination
It works by plugging the connection cable into the microscope
and the electricity supply. The On/off switch (Fig. 16, 2) must
be switched on.
Your microscope is equipped with a built-in rechargeable
battery. This has a charge time of 16 hours, when it is com-
pletely discharged. A fully charged battery allows hours of ob-
servation. Before using the microscope for the first time the
rechargeable battery should be charged for 16 hours. Please
charge it by connecting the microscope to power outlet using
the included AC adapter (Fig. 14).
3. Microscope setup
The microscope's viewing (Fig. 1-4) will now be prepared for
the first observation. First, rotate the eyepiece into a conven-
ient position. Begin every observation with the lowest magnifi-
cation. Place the microscope stage (Fig. 1, 8) with the focus
knob (Fig. 1, 9) into the lowest position and rotate the objective
revolver (Fig. 1, 6) until it locks on the lowest magnification (4x).
- 10 -
J
Focus wheel
1)
Colour filter disc
1!
Electric illumination
1@
Microscope base
O
Object clip
A
O
Vernier scale
B
O
X – axis
X
O
Y – axis
Y
Fig. 11 Preparation kit
Fig. 12 Shrimp hatchery
Fig. 13 Preparation aids
Fig. 14 AC adapter
Fig. 15 1. LED status
2. Power supply cord
Fig. 16 1. Brightness control
2. On/off switch
Fig. 17 create preparation
Fig. 18 cover preparation
Tabla de contenido
loading

Tabla de contenido