10. Troubleshooting
Fault
Engine does not
start
Generator has too
little or no
voltage
The battery does
not charge up
Starter does not
turn
Anl_TC_PG_65_E5_SPK13.indb 26
Anl_TC_PG_65_E5_SPK13.indb 26
GB
Mögliche Ursache
Automatic oil cut-out has not respon-
ded
Spark plug fouled
No fuel
Controller or capacitor defective
Overcurrent circuit-breaker has
triggered
Air fi lter dirty
Poor contact to the battery
Battery defective
12 V safety trip has been triggered.
Battery discharged
Battery not connected
- 26 -
Behebung
Check oil level, top up engine oil
Clean or replace spark plug (electro-
de spacing 0.6 mm)
Refuel / have the petrol cock checked
Contact your dealer
Actuate the circuit-breaker and
reduce the consumers
Clean or replace the fi lter
Clean the contacts
Have the battery checked by an ex-
pert and replace it if necessary
Check the function of the equipment
using a diff erent battery; Actuate the
12 V safety trip.
Charge the battery
Connect the battery