REPLACING THE PRIMARY FILTER
1. Release the latches "A" and remove the Venturi power-head "B" (Figure 3).
2. Remove the four screws "C" from the Diaphragm "D" (Figure 4)
3. Remove the Diaphragm "D" (Figure 5).
4. Remove the old Primary Filter "E" (Figure 5)
5. Install the new Primary Filter "E" inside a Cap "F" (Figure 5)
6. Reinstall the Diaphragm"D" and tighten the screws "C" (Figure 4).
8. Mount the suction unit "B" onto the machine and secure
in place with the latches "A" (Figure 3).
9. Dispose of the old filter in accordance with all federal,
state and local regulations.
INSTRUCTIONS FOR USE
3
C
4
D
D
5
E
F
PAGE 6