CABLE CALIBRATION

Procedure for calibrating the charging cables of the device, so that the charger optimally compensates for the voltage
drop due to the cables. It is strongly recommended to perform this procedure each time the cables are modified or
changed.
1. Enter one of the lead charging modes.
2. Short-circuit the 2 clamps of the cable (do not short-circuit a battery).
3. Unplug the product from the mains and wait until the charger switches off.
4. Press and hold button
-
lit: Calibration has been performed correctly.
- Light
on: calibration failed, disconnect the power plug and repeat the procedure.
5. Unplug the mains plug until the charger switches off.

CHARGE MODES

Lead/Liquid (28.8 V/15 A) charging mode:
Mode designed for the recharge of 24V lead/GEL batteries from 30 Ah to 240 Ah. 6-step automatic char-
ging cycle.
Lead/Liquid-Traction (28.8 V/15 A) charging mode:
Mode designed for charging 24V lead/liquid traction batteries from 30 Ah to 240 Ah. 6-step automatic
charging cycle.
Lead/AGM (29.6 V/15 A) charging mode:
Mode designed for the recharge of 24V lead/AGM batteries from 30 Ah to 240 Ah. 6-step automatic char-
ging cycle.
Lead/AGM-Traction (29.6 V/15 A) charging mode:
Mode designed for charging 24V lead/AGM-traction batteries from 30 Ah to 240 Ah. 6-step automatic
charging cycle.
Lithium Iron Phosphate charging mode (28.8 V/15 A):
Mode for charging 24 V lithium LiFePO4 batteries from 15 Ah to 240 Ah. 6-step automatic charging cycle.
Li-ion
Charging mode Lithium-ion (25.2V/15A) :
Mode for charging 24V lithium-ion batteries from 15Ah to 240Ah. 6-step automatic charging cycle.
GYSFLASH 15.24 PL-E
while plugging in the mains socket until indicator
Some Lithium batteries incorporate a UVP protection (Under Voltage Protection) which dis-
connects the battery in case of deep discharge. This protection prevents the charger from
detecting the battery. In order for the Gysflash 15.24 PL-E to be able to charge the battery, it
is necessary to deactivate the UVP protection. To do this, set the charger to Lithium charging
mode, unplug the charger until the product turns off. Press and hold button
ging in the product's power outlet. The charger will then deactivate the UVP protection and
automatically start charging.
Caution: In case of UVP protection of a lithium battery, remove all consumers on the battery
before activating the UVP Wake up.
or
lights up.
while plug-
EN