The fitting must installed, flushed and
tested after the valid norms!
Assembly
1. Flush through the supply pipes.
2. Place the mixer including the sealing washer
in position on the sink.
3. Slip the plastic washer, the slide washer, the
metall washer and collar nut over the hose
and threaded base and tighten the collar nut
by hand. If there is not enough space, please
use only the slide washer and the metall with-
out the plastic washer.
4. Tighten screws.
5. Connect the connecting hose / supply pipes
to the angle valves;
cold right - hot left.
Large differences in pressure between the hot
and cold water supply should be balanced.
Operation
The mixer is activated by pulling the lever han-
dle.
Turning to the left = cooler water,
turning to the right = warmer water.
Technical Data
Operating pressure:
Recommended operating pressure: 1 - 5 bars
Test pressure:
Hot water temperature:
Recommended hot water temp.: 65° C
Rate of flow:
Hansgrohe single lever mixers can be used
together with hydraulically and thermically con-
trolled continuous flow heaters if the flow pres-
sure is at least 1.5 bars.
To adjust the hot water limiter on single lever mix-
ers, please see page 14.
No adjustment is necessary when using a con-
tinuous flow water heater.
6
English
max. 10 bars
16 bars
max. 80° C
13 l/min 3 bars
Spare parts
1
llever head
1.1 screw cover
2
flange
3
nut
4
cartridge cpl.
5
aerator cpl.
6
fixation cpl.
7
connection hose 600 mm
8
spout cpl.
9
sealing set
10
supply pipe 490 mm
38091000
96338000
96468000
96461000
92730000
13913000
95049000
97398000
92830000
92646000
96786000