WEBTEC FlowHUB Serie Manual Del Usuario página 6

Ocultar thumbs Ver también para FlowHUB Serie:
Idiomas disponibles

Idiomas disponibles

Functional Specification
Flow range: see model configuration
l
Pressure range: see model configuration
l
Ambient operating temperature: - 5 to 40 °C
l
Fluid type: hydraulic oil
l
Fluid temperature: 5 to 90 °C
l
Accuracy: ± 3% of full scale at 21 cSt (higher
l
accuracy on request)
Repeatability: better than ± 1%
l
Response time: 150 ms (Switch and Transmitter),
l
50 ms (Ultimate)
Protection: designed to meet IP64
l
Electrical specification
Supply voltage: 15 to 30 VDC class 2 supply only
l
Typical current: 35 mA
l
Maximum current excluding switch current: 60 mA
l
Switch current: 500 mA per switch max.
l
Switch Voltage: supply voltage - 0.5 V
l
Connector type: M12 - 5 pin male
l
Voltage output: minimum load = 10K Ohms
l
Current output: maximum load = (supply voltage x
l
46) - 200 ohms
Recommended cable: screened cable, 5 x 0.25(2)
l
(24AWG)
All manuals and user guides at all-guides.com
Pin Connection Details
4
1 - + supply
2 - switch 1 *
3 - GND
4 - switch 2 *
5 - Analogue out: either 0 - 5V or
4 - 20 mA *
* These are options according to model and
may not be operational.
3
2
5
1
3
loading