Venting Requirements; Earthing Instructions; Important - Whirlpool 8528095 Instrucciones De Instalación

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Recommended Earthing Method
It is your responsibility to contact a qualified electrical installer
to ensure that the electrical installation is adequate and in
conformance with the National Electrical Code, ANSI/NFPA 70,
latest edition, and all local codes and ordinances.

EARTHING INSTRUCTIONS

For an earthed, cord-connected dryer:
This dryer must be earthed. In the event of a malfunction or
breakdown, earthing will reduce the risk of electric shock by
providing a path of least resistance for electric current. This
dryer uses a cord having an equipment-earthing conductor
and an earthing plug. The plug must be plugged into an
appropriate outlet that is properly installed and earthed in
accordance with all local codes and ordinances.
For a permanently connected dryer:
This dryer must be connected to a earthed metal, permanent
wiring system, or an equipment-earthing conductor must be
run with the circuit conductors and connected to the
equipment-earthing terminal or lead on the dryer.
WARNING:
Improper connection of the equipment-
earthing conductor can result in a risk of electric shock.
Check with a qualified electrician or service representative or
personnel if you are in doubt as to whether the dryer is
properly earthed. Do not modify the plug on the power
supply cord: if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
SAVE THESE INSTRUCTIONS
All manuals and user guides at all-guides.com

Venting Requirements

WARNING
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death
or fire.
WARNING:
To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS.
The dryer vent must not be connected into any gas vent,
chimney, wall, ceiling, or a concealed space of a building, or
any other vent used for venting.
Do not use an exhaust hood with a magnetic latch.
Do not install flexible metal vent in enclosed walls, ceilings or
floors.
10 cm (4") heavy metal vent and clamps must be used.
Use clamps to seal all joints. Vent must not be connected or
secured with screws or other fastening devices which extend
into the interior of the vent. Do not use duct tape.
IMPORTANT: Observe all governing codes and ordinances.
Use a heavy metal vent. Do not use plastic or metal foil vent.
Rigid metal vent is recommended to prevent crushing and
kinking.
Flexible metal vent must be fully extended and supported when
the dryer is in its final position. Remove excess flexible metal vent
to avoid sagging and kinking that may result in reduced airflow
and poor performance.
An exhaust hood should cap the vent to prevent rodents and
insects from entering the home or business.
Exhaust hood must be at least 30.5 cm (12") from the ground or
any object that may be in the path of the exhaust (such as
flowers, rocks or bushes).