PRE-DIVE PROCEDURES

WARNING
Do not attempt to connect low pressure hoses to the high pressure ports with the use
of an adapter. Improper connection will cause damage to the equipment and could
result in serious personal injury. Low pressure components are not intended to
withstand pressures greater than 28Bar ≒ (400 PSI). When installing your accessory
hoses, avoid damaging the O-ring. Tighten gently, but firmly into the first stage housing.
SCUBA complying with EN 250 are not intended for more than one user to breathe from
at the same time.
If SCUBA are configured and used by more than one diver at the same time, then the
cold water and breathing performances may not fulfil the requirements of EN 250.
RS-350, 340
Always connect the Octopus Regulator to the portmarked with SS. Connecting to any
other port is strictly prohibited.
PRE-DIVE OPERATING INSTRUCTIONS
1.
Position the tank valve so the outlet points toward the diver.
2.
Remove the dust cap from the first stage inlet and place the yoke (or DIN adaptor)
in the center of the cylinder valve connection.
3.
Position the first stage body so that the second stage hose goes over the right
shoulder of the diver.
4.
Hand-tighten the yoke screw or DIN adoptorscrew.
5.
Check all the hose connections to the first and second stages. If they can be
loosened by hand, they should be tightened with a wrench before pressurizing.
6.
Check the submersible pressure gauge to make sure it indicates zero pressure.
7.
Open the tank valve slowly to gradually allow air into the regulator.
NOTE: During this operation, depress the second stage purge button to reduce
shock to the valve mechanism. Do not perform this operation in a cold environment
below 10°C (50°F). Performing this in a cold environment may cause "freeze-up" of
the regulator which can render it inoperable. If this occurs, you should contact a
TUSA authorized service center.
8.
Check the submersible pressure gauge to ensure that it indicates the proper tank
pressure.