15
Final current
Permits adjustment of the final current.
Parameter set in Amps (A).
Minimum 3A-1%, Maximum Imax-500%, Default 50%
17
Post-gas
Permits setting and adjustment of the gas flow at the
end of welding.
Minimum 0.0s, Maximum 99.9s, Default 5.0s
18
TIG start (LIFT)
Allows selection of the required arc striking modes.
On= HF START, Off= LIFT START, Default HF START
22
Spot welding
Allows you to enable the "spot welding" process and
establish the welding time.
Allows the timing of the welding process.
Parameter setting: seconds (s).
Minimum off, Maximum 99.9s, Default 1.0s
25
Wire speed
Allows the regulation of the wire feed rate.
Parameter setting: mm/s.
Minimum 1 mm/s, Maximum 200 mm/s, Default Off
26
Wire start delay
Parameter setting: seconds (s).
Minimum 0.1s, Maximum 99.9s, Default Off
27
Wire stop advance/delay
Parameter setting: seconds (s).
Minimum 0.1s, Maximum 99.9s, Default Off
28
Wire withdrawal
Parameter setting: seconds (s).
Minimum 0.01s, Maximum 1.00s, Default 0.10s
29
Slope-down
Parameter setting: seconds (s).
Minimum 0.0s, Maximum 10.0s, Default 0.0s
30
Basic wire speed
Parameter setting: percentage (%).
Minimum 0%, Maximum 100%, Default 0%
100%
=
0%
= 0
= wire withdrawal
31
Slope-up (wire speed)
Parameter setting: seconds (s).
Minimum 0.0s, Maximum 10.0s, Default 0.0s
32
Pulsed frequency (wire speed)
Allows activation of the pulse mode.
Permits adjustment of the pulse frequency.
Parameter set in Hertz (Hz).
Minimum 0.1Hz, Maximum 5.0Hz, Default Off
0.1÷5.0Hz
pulsed frequency (wire speed)
off
pulsed frequency (wire speed) = 0
syn
pulsed frequency (wire speed) =
pulsed frequency (current)
33
Duty cycle (wire speed)
Allows regulation of the duty cycle in pulse welding.
Parameter setting: percentage (%).
Minimum 1%, Maximum 99%, Default 50%
34
Unbalance (wire speed)
Parameter setting: percentage (%).
Minimum -50%, Maximum +50%, Default 0%
37
Guard limits
Allows the setting of the warning limits and of the guard
limits.
Allows the accurate control of the various welding
phases (consult the "Guard limits" section).
38
All manuals and user guides at all-guides.com
38
39
40
41
42
44
45
46
47
48
49
50
99
3.9 Programs screen
1
Starting filter
Allows the control of the guard limits to be enabled
with an adjustable delay in relation to the arc striking.
Makes it possible to filter the striking phase (consult the
"Guard limits" section).
Minimum 0.0s, Maximum 10.0s, Default 0.0s
Output filter
Makes it possible to disenable the control of the guard
limits in advance of the natural closing of the weld.
Makes it possible to filter the extinction phase (consult
the "Guard limits" section).
Minimum 0.0s, Maximum 10.0s, Default 0.0s
Current reading
Allow the real value of the welding current to be dis-
played.
Allows the welding current display method to be set
(consult the "Interface personalisation" section).
Voltage reading
Allows the real value of the welding voltage to be dis-
played.
Allows the welding voltage display method to be set
(consult the "Interface personalisation" section).
Gas flow reading
(U/D) Adjustment step
Permits adjustment of the variation step on the up-
down keys.
Minimum Off, Maximum MAX, Default 1
CH1 External parameter
Allows the management of external parameter 1 (mini-
mum value, maximum value).
(Consult the "External controls management" section).
CH2 External parameter
Allows the management of external parameter 1 (mini-
mum value, maximum value).
(Consult the "External controls management" section).
Lock/unlock
Allows the locking of the panel controls and the inser-
tion of a protection code (consult the "Lock/unlock"
section).
Buzzer tone
Permits adjustment of the buzzer tone.
Minimum Off, Maximum 10, Default 5
Contrast
Permits adjustment of the display contrast.
Minimum 0, Maximum 50, Default 25
Allows access to the higher set-up levels:
USER: user
SERV: service
SELCO: Selco
Reset
Allows the resetting of all parameters to the default
values.
Allows the resetting of the whole graphic interface
according to the manufacturer's settings.
General
Allows the storage and management of 50 welding pro-
grams which can be personalised by the operator.