iNSTallaTiON
Specification
15.2.1 Cleaning the strainer, standard installation on finished
walls
f Isolate the appliance from the power supply.
f
f Close the shut-off valve in the cold water inlet line.
f
f Open all draw-off valves.
f
f Remove the cold water threaded fitting.
f
f Remove the strainer from the twin nipple using a flat-blade
f
screwdriver. Clean the strainer.
f Reinsert the strainer. Screw the cold water connection pipe
f
onto the twin nipple.
f Open the shut-off valve in the cold water inlet line.
f
f Open and close all connected draw-off valves several times,
f
until all air has been purged from the pipework and the
appliance.
f Switch on the power supply.
f
15.2.2 Cleaning the strainer, installation on unfinished walls
f Isolate the appliance from the power supply.
f
f Close the shut-off valve in the cold water inlet line.
f
f Open all draw-off valves.
f
f Open the appliance by undoing the screw and lifting up the
f
appliance cover.
f Unscrew the cold water connection pipe from the twin nip-
f
ple. Pivot the cold water connection pipe upwards.
f Remove the strainer from the twin nipple. Clean the strainer.
f
f Screw the cold water connection pipe and the strainer with
f
sealed edge onto the twin nipple.
f Open the shut-off valve in the cold water inlet line.
f
f Open and close all connected draw-off valves several times,
f
until all air has been purged from the pipework and the
appliance.
f Check the cold water connection for leaks.
f
f Hook the appliance cover into the appliance back panel at the
f
top rear. Pivot the appliance cover downwards. Check that
the appliance cover is securely seated both top and bottom.
Secure the appliance cover with the screw.
f Switch on the power supply.
f
14
| DCE-S Plus
16. Specification
16.1 Dimensions and connections
217
140
175
b02
100
c06
b02 Entry for electrical cables I
c01
Cold water inlet
c06
DHW outlet
Alternative connection options
b03
b02
c06
b02 Entry for electrical cables I
b03 Entry for electrical cables II
c01
Cold water inlet
c06
DHW outlet
97
32
35
c01
109
DCE-S Plus
Finished walls
Male thread
Male thread
b02
30
b03
b02
15
b02
100
c01
DCE-S Plus
Finished walls
Unfinished walls
Male thread
Male thread
www.stiebel-eltron.com
G 1/2 A
G 1/2 A
G 1/2 A
G 1/2 A