Error Codes; Technical Data - LaserLiner DistanceMaster Compact Pro Manual De Instrucciones

Ocultar thumbs Ver también para DistanceMaster Compact Pro:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 44

Error codes:

Err101: Replace the battery
Err104: Calculation error
Err152: Temperature is too high: > 40°C
Err153: Temperature is too low: < 0°C
Err154: Outside the measuring range
Err155: Received signal too weak
Err156: Received signal too strong
Err157: Incorrect measurement or background is too bright
Err160: The device is moving too much to measure
Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning agents,
scouring agents and solvents. Remove the battery(ies) before storing
for longer periods. Store the device in a clean and dry place.
Calibration
The meter needs to be calibrated and tested on a regular basis to ensure
it produces accurate measurement results. We recommend carrying out
calibration once a year.

Technical Data

(Subject to technical changes without notice. Rev18W48)
Distance measurement
Precision (typical)*
Inside measurement range**
Angle measurement
Measuring range
Resolution
Precision
Laser class
Laser wavelength
Operating conditions
Storage conditions
Radio module
operating data
Automatic switch-off
Power supply
18
EN
± 2 mm
0,1 m - 50 m
± 90°
0,1°
0,1°
2 < 1 mW
650 nm
-10°C ... 40°C, max. humidity 80% rH,
no condensation, max. working altitude
2000 m above sea level
-20°C ... 70°C, max. humidity 80% rH
Bluetooth LE 4.x interface; Frequency
band: ISM band 2400–2483.5 MHz,
40 channels; Transmission power:
max. 10 mW; Bandwidth: 2 MHz;
Bit rate: 1 Mbit/s;
Modulation: GFSK/FHSS
30 sec laser / 10 min device
2 x AAA 1.5 Volt batteries
Tabla de contenido
loading

Tabla de contenido