Important notices
• The laser points to the location that will be measured.
No objects may get into the laser's line of measurement.
• The device compensates the measurement for different room
temperatures. Therefore allow the device a brief adaptation period
when changing locations with large temperature differences.
• The device is only conditionally useable in outdoor areas and cannot
be used in strong sunlight.
• The measurement results of outdoor measurements may be influenced
or falsified by rain, fog and snow.
• In unfavourable conditions, e.g. with poorly reflecting surfaces,
the maximum deviation may be greater than 3 mm.
• Carpeting, upholstery or curtains will not reflect the laser optimally.
Measure to flat surfaces.
• Measurements made through glass (window panes) can falsify
measurement results.
• An energy-saving function switches the device off automatically.
• Clean with a soft cloth. Water may not be allowed to penetrate
the housing.
Error codes:
204
Calculation error
208
Excess current (please contact your retailer)
220
Replace the battery
252
Temperature is too high
253
Temperature is too low
255
Received signal too weak or measuring time too long
256
Received signal too strong
251
Outside the measuring range
500
Hardware fault (If the symbol stays on after switching the device
off and on, please contact your retailer.)
Information on maintenance and care
Clean all components with a damp cloth and do not use cleaning agents,
scouring agents and solvents. Remove the battery(ies) before storing for
longer periods. Store the device in a clean and dry place.
Calibration
The measuring device should be calibrated and tested on a regular basis
to ensure it is accurate and working properly. We recommend carrying
out calibration once a year. If necessary, contact your distributor or the
UMAREX-LASERLINER service department.
18