Tabla de contenido
Idiomas disponibles

Idiomas disponibles

5. DMX CONNECTION AND DMX PROTOCOL

DMX addressing

The device is controlled by universal DMX 512
protocol, DMX address is the start channel used
to receive instructions from the external control-
ler. For independent control, each fixture must
be assigned its unique address control channels.
For example, this device has four channel modes:
19/41/170/19/21, if we set the mode at standard 19
channels mode, and there are several models need
to be independently controlled, we just simply
address first fixture at 1, and second fixture at 20,
third one at 39, etc.
If the devices have the same address, they will
behave synchronically. DMX addressing is limited,
don't set the address so high that without enough
control channels for the fixtures. Display is flashing
when no DMX signal is received.
Connection: use DMX cable with 5 pin XLR-plugs
to connect the controller with the fixture or one
fixture with another.
This device is equipped with 3-pins DMX in and
out sockets only.
Pin 1 = GND | Pin 2 = Signal (-) | Pin 3 = Signal (+) |
Pin 4 = N.A. | Pin 5 = N.A.
The termination is prepared by soldering a 120Ω
resistor between pins 2 and 3.
P. 11
English version
- Neo ION 3715Z
Tabla de contenido
loading

Tabla de contenido