50 | English
The <Signal View> displays the signal strength at each measuring point without informa-
tion on the object depth.
The <Signal View> can be used to locate closely adjacent objects and to better assess
complicated material structures based on the signal path.
Follow the instructions on the measuring process in <Object View>.
Measuring Mode <Leakage Detection>
In this measuring mode, the relative material moisture of the surface is displayed. It is
therefore suitable for locating the point of maximum material moisture and thus a pos-
sible leakage.
Different materials on the surface, flat lying objects and inhomogeneities in the substrate
(such as joints) can distort the result.
Measuring Mode <Distance Measurement>
In this measuring mode, you can measure distances on the wall. It is only possible to take
this measurement in a straight line in the direction of travel of the wheels.
Place the measuring tool onto the wall at the starting point for the measurement. The ref-
erence point of the measurement is always the top marking aid (1). If necessary, press
the red start button (16) to delete the displayed measured value and to start a new
measurement.
Move the measuring tool over the wall in a straight line in the required direction while ap-
plying uniform pressure. The distance to the starting point is continuously measured.
The measured value shown on the display is the distance to the starting point for the cur-
rent measurement, not the total distance travelled (as you move the tool back towards
the starting point, the measured value will be smaller).