Troubleshooting - MoistAir HD1407 Oak Manual Del Proprietário

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Troubleshooting

Trouble
Digital display not
illuminated.
Fan not operating
(digital display is
illuminated).
Fan running
continuously.
Poor evaporation of
water.
Neither bottle
emptying.
Bottles continue to
empty after complete
filling.
Left bottle not
emptying.
Bottle empties
completely
Refill display "F" is on
before bottles are
empty.
"CF" message does
not appear even when
filter is dirty or
humidifier performance
is clearly reduced.
Display blinks or fan
moves slightly when
humidifier is plugged in.
Probable Cause
• No Power.
• Power button has not
been depressed.
• ROOM humidity level is
not 3% or more below
SET humidity level.
• Reservoir is empty.
• Float is obstructed.
• SET humidity level is
65%.
• ROOM humidity level
has not reached 1% or
more above SET
humidity level.
• CHECK FILTER (CF)
message flashing.
• Mineral buildup on filter.
• Bottle cap plunger
missing post in bottom of
cabinet
• Dirty filters.
• Air is entering water
bottle.
• Right bottle contains
water.
• This is normal for initial
filling
• Unit is not set up on a
level surface. (Float
will not sense water at
the front of the
cabinet.)
• Loss of power or a
power failure has caused
the CF message to
prematurely reset.
• Normal
13
Remedy
• Check 120 volt power source.
• Press power button once to
turn on.
• Raise SET humidity level if desired.
• Increase fan speed.
• Fill humidifier with water.
• Free float from obstruction
• A SET humidity percentage of 65%
operates fan continuously. Adjust
SET level between 25% - 60%.
• Continue to run until desired
humidity level is achieved. This
may take up to 48 hours initially.
• Change to a fresh new filter.
NOTE: Local water varies from area
to area and under certain conditions
minerals will build up more rapidly in
the filter.
•Unplug unit for 1-2 minutes to reset
CF function
• Check orientation of bottles.
Reposition so that bottle cap
plunger (stem) is depressed by
post in bottom of cabinet.
• Change to fresh new filters
(HDC12).
•Check "Side-Fill Caps" and valve
assembly caps to ensure tightness.
• Check for leak in water bottle.
• Ensure gaskets for "Side Fill Caps"
are in place.
•The humidifier is designed so that
right bottle empties first.
• Ensure unit is level - Install caster
pads on front casters, as needed.
• Refill bottle for maximum
run time.
•Position unit level. (Some carpet
padding may allow unit to sit lower in
the front than rear with the additional
weight of water bottles in the front of
the cabinet. Install caster pads under
front casters (see page 5).
• Replace filter.
• No action required.
.
Tabla de contenido
loading

Este manual también es adecuado para:

Hd1409 brushed nickel

Tabla de contenido