Metabo HG 16-500 Manual Original página 9

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
direct at the same point for long
periods.
Heat can be directed to concealed
combustible materials.
Never direct the hot-air blower at
highly flammable materials! Fires
can be caused if the hot-air blower
is not used with great care.
Never leave the tool unattended
when it is running.
After long periods of use at
maximum temperature, the
temperature should be lowered
before the tool is switched off. This
lengthens the service life of the
heater.
Place the tool on the bases
provided following use and wait
until it has cooled down before
placing in storage!
Store your tools in a safe place.
Unused tools should be stored in a
dry, locked room inaccessible to
children.
Always take care where there are
toxic gases and a risk of explosion.
Toxic can be created when
working on plastics, paints and
similar materials. Risk of fire and
combustion!
Only use the hot-air blower in well-
ventilated rooms!
Never inhale the vapours created!
For your own safety, only use
accessories and auxiliary devices
specified in the Operating
Instructions or recommended or
specified by the tool manufacturer.
The use tools or accessories other
than those recommended in the
Operating Instructions or in the
catalogue can result in a risk of
injury.
5. Overview
See page 2.
1 Stainless steel blow-out pipe
2 Detachable protective tube (for areas that are
difficult to access)
3 Air inlet (for HGS... with fine dust filter)
4 Sliding switch (On-off switch/stepping switch)
5 Anti-slip bases (for non-tilting and anti-slip
stationary work applications)
6 Adjusting wheel for setting the temperature*
7 Display* (for temperature and air volume)
8 Button for setting the air volume*
9 Program selection button*
10 Joystick for setting the temperature and air
volume*
* depending on the features / model
6. Use
Before commissioning, check that the rated
mains voltage and mains frequency stated on
the type plate match your power supply.
The distance to the object being processed
depends on the material and intended
processing type. Always first carry out an inspection
of air volume and temperature! The attachable
nozzles (see chapter 9.) available as accessories
can be used for precise hot air control to a specific
point or a surface.
Take care when changing hot nozzles! Danger
of burns.
6.1
HG 16-500
The sliding switch (4) can be used to switch the tool
on and off for selecting between 2 stages (for air
volume and temperature).
Stage 1: 300 °C, 240 l/min
Stage 2: 500 °C, 450 l/min
6.2
HG 20-600
The sliding switch (4) can be used to switch the tool
on and for selecting between 3 stages.
The air volume varies in the 3 stages
(150/300/500 l/min).
At stage 1 of the sliding switch (4) the temperature
is always 80 °C (cold-air stage). Use the cold-air
stage to dry paint, cool workpieces or to cool down
the nozzle before changing an accessory part.
At stage 2 and 3 of the sliding switch (4), the
temperature can be set steplessly at the adjusting
wheel (6).
ENGLISH en