required to cool the Inverter if needed. If the temperature reaches
approximately 80°C the Inverter will shut down automatically. Turn off the
Inverter and allow it to cool for a minimum of 15 minutes. Before starting up
again, verify the total wattage of the devices being powered.
To Reset the Inverter
1. Turn off the Inverter using the ON/OFF switch on the Inverter, depending
upon how the Inverter was controlled.
2. Unplug all devices.
3. Turn the Inverter back on using the ON/OFF switch on the Inverter. Before
devices are reconnected, verify the total wattage of the devices to ensure they
are less than the rating of the Inverter.
TROUBLESHOOTING
Problem
No Power on
Low
Voltage
alarm turns on
immediately
Low
voltage
alarm is on all
the time
Situation
Fault
connection
Battery voltage
below
10
Voltage
Equipment
being operated
draws
too
much power
The
input
voltage at input
of the Inverter
needs
to
be
raised
Power battery
condition
with
voltage drops
Inadequate
power
or
voltage drops
Action
Turn the Inverter power switch off; Verify
cable are tightly connected to the Inverter
and the power Source
Recharge or replace battery
Allow Inverter to cool down. Ensure
there's adequate ventilation around the
Inverter. Ensure that load is no more than
it's maximum rating for continuous
operation
Recharge/Replace
additional batteries. Run the vehicle
engine when using a 12V DC plug
Replace battery
Check condition of battery cables and
cable
leads.
necessary
battery
Clean
or
replace
or
add
as