FIGURE [2]
A: Connection Valve
B: Gas Canister
C: Fuel Hose
D: Burners
Optional Parts: (not included with initial purchase)
H: EN417/CGA600 Valve Connector
I: Propane Gas Hose CGA600/QCC1
TECHNICAL SPECIFICATIONS
Gas Category: direct vapour pressure I3B/P – butane/
isobutane/propane mix. Combustibles: Use only Optimus
100,110,220,230,450g gas cartridges certified to the EN417
standard. US/Canada only: Alternatively, a refillable bulk
LP-gas tank with a max. capacity of 20 lbs (9 kg) may also be
used with an adapter (Optimus Adapter sold separately). Only
use hoses certified to UL569,CSA8.1 or CSA8.2 to connect to
the adapter. It may be hazardous to attempt to fit other types
of gas canisters.
Gas Consumption (per burner): EU: 2.3kW nominal EN521
US/CA: EN417 disposable gas cartridges: 3.4kW; 240g/h;
11'600BTU/h. Refillable propane cylinder max 20 lbs(9kg):
1.8kW; 6'200BTU/h
Injector size of stove: 0.37mm
1
SET UP STOVE
1. Lay out fuel hose to full length and make sure that it is not
twisted in any place.
2. Check the O-ring in the valve connector before each use
for damage (see under 5. Maintenance).
3. Fold out legs of the stove. Legs are in place when unfolded
until resistance is felt.
4. Fold out both control valve handles and make sure that
they are fully closed (turned fully clockwise), even if only
one burner will be used.
E: Pot Support
F: Pot Support/Legs
G: Gas Flow Regulators
FIGURE [3]
FIGURE [4]
FIGURE [1]
EN
EN
EN
FR
DE
NL
DK
SWE
NO
FI
IT
ES
PT
PL
CZ
RU
3