Safety Rules 1 - HAMPTON BAY Umber Manual Del Propietário

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

To reduce the risk of electric shock, insure electricity
1.
has been turned off at the circuit breaker or fuse box
before beginning.
All wiring must be in accordance with the National
2.
Electrical Code ANSI/NFPA 70-1999 and local electrical
codes. Electrical installation should be performed by a
qualified licensed electrician.
WARNING: To reduce the risk of fire or electric shock, do
3.
not use this fan with any solid-state speed control device.
CAUTION: To reduce the risk of personal injury, use only
4.
the screws provided with the outlet box.
The outlet box and support structure must be securely
5.
mounted and capable of reliably supporting 35 lbs. (15.9kg).
Use only UL Listed outlet boxes marked "Acceptable for
Fan Support of 35 lbs. (15.9kg) or less."
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL
INJURY, MOUNT TO OUTLET BOX MARKED "ACCEPTABLE FOR FAN
SUPPORT OF 35LBS. (15.9KG) OR LESS", AND USE SCREWS PRO-
VIDED WITH THE OUTLET BOX.
The fan must be mounted with a minimum of 7 feet
6.
clearance from the trailing edge of the blades to the floor.
Do not operate reversing switch while fan blades are in mo-
7.
tion. Fan must be turned off and blades stopped before re-
versing blade direction.
Avoid placing objects in path of the blades.
8.
To avoid personal injury or damage to the fan and other items,
9.
be cautious when working around or cleaning the fan.
READ AND SAVE THESE INSTRUCTIONS
Do not use water or detergents when cleaning the fan or fan
10.
blades. A dry dust cloth or lightly dampened cloth will be
suitable for most cleaning.
After making electrical connections, spliced conductors
11.
should be turned upward and pushed carefully up into
outlet box. The wires should be spread apart with the
grounded
conductor
conductor on one side of the outlet box.
Electrical diagrams are for reference only. Light kits that
12.
are not packed with the fan must be UL listed and marked
suitable for use with the model fan you are installing. If us-
ing this fan in a wet or damp environment, light kit must be
marked "Suitable for Use in Wet Location". Switches must
be UL General Use Switches. Refer to the instructions pack-
aged with the light kits and switches for proper assembly.
SUITABLE FOR USE IN WET LOCATIONS when
13.
installed in a GFCI protected branch circuit.
All set screws must be checked and retightened where
14.
necessary before installation.
TO REDUCE THE RISK OF PERSONAL INJURY, DO NOT BEND THE
BLADE BRACKETS (ALSO REFERRED TO AS "FLANGES") DURING
ASSEMBLY OR AFTER INSTALLATION. DO NOT INSERT OBJECTS IN
THE PATH OF THE BLADES.
PLEASE REMOVE RUBBER MOTOR STOPS ON THE BOTTOM OF THE
FAN BEFORE INSTALLING BLADES OR TESTING THE MOTOR.
and